7.

OPERATING INSTRUCTIONS

 

 

FOR YOUR SAFETY READ BEFORE OPERATING 

WARNING:

 IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION  

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. 

 
A)

 

This appliance is equipped with a pilot, which 
must be lit by hand by following these 
instructions exactly. 

B)

 

BEFORE LIGHTING smell all around the appliance 
area for gas, and next to the floor because some 
gas is heavier than air and will settle on the floor. 

WHAT TO DO IF YOU SMELL GAS

:   

 

Do not try to light any appliance. 

 

Do not touch any electrical switch; do not 
use any phone in your building. 

 

Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas supplier’s 
instructions. 

 

 

If you cannot reach your gas supplier, call 
the fire department. 

C)

 

Use only your hand to push in or turn the gas 
control knob.  Never use tools.  If the knob will 
not push in or turn by hand, do not try to repair 
it .  Call a qualified service technician.  Force or 
attempted repair may result in a fire or explosion. 

D)

 

Do not use this appliance if any part has been 
under water.  Immediately call a qualified service 
technician to inspect the appliance and to replace 
any part of the control system and any gas 
control which has been under water 

LIGHTING INSTRUCTIONS

 
1.

 

STOP!  Read the safety information above.  

2.

 

Turn off all electrical power to the appliance. 

 
3.

 

Turn the gas control knob 
clockwise to the “off’ position. 

4.

 

Open door. 

 Wait five (5) minutes to clear out 

any gas

.  Close door.  If you smell gas including 

near the floor, 

STOP!

 Follow  “B” in the above 

safety information. 

If you don’t smell gas go to next step. 

5.

 

Find the pilot located to the right between the 
front and rear burner. 

6.

 

Turn gas control knob counter-clockwise to 
“PILOT”. 

7.

 

Push the gas control 

knob in 

fully and hold.  Immediately light the pilot by 
pushing the piezo spark igniter.  Keep knob 
depressed for about 30 seconds after pilot is lit.  
Release knob.  If pilot goes out, repeat steps 4 
through 6.  

WARNING; The gas valve has a lockout device, 

which will not allow the pilot burner to be re-lit 
until the thermocouple, has cooled. 

If the knob does not pop up when released, stop 
and immediately call your service technician or 
gas supplier. 

 

 NOTE:  Check to be sure the pilot flame engulfs the 

thermocouple

 and that the burners light 

completely. 

 

If the pilot will not 
stay lit after 
several tries, turn 
the gas control 
knob to “OFF" and 
call you service 
technician or gas 
supplier. 

 

HI \ LO knob 

Control knob 

Turn gas control knob counter-clockwise to   the 
“ON” position. 
 

Flip burner switch to “ON” 
then turn “HI / LO” knob to the desired setting. 

 
8.

 

Turn on all electrical power to the unit

 

 

TO TURN OFF GAS TO 

APPLIANCE

1.

 

Turn the gas control  knob 

clockwise to “OFF” DO NOT FORCE  

 

12

Содержание EG-40 FPI. BV.

Страница 1: ...information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life A qualified installer service agency or the gas supplier must...

Страница 2: ...installation must conform with local codes or in the absence of local codes with the current CAN CGA B 149 installation code in Canada or the National Fuel Gas Code ANSI Z223 1 2 in the USA To preven...

Страница 3: ...certified chimney liner kit Has been certified for use with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bedsitting room Must be installe...

Страница 4: ...approved methods 4 Place the electric cable so it can be connected to the power supply Push the unit into its final position in the fireplace insuring that it is stable and level Using the leveling le...

Страница 5: ...14 Wipe down all gold surfaces with a soft rag to remove fingerprints they may become etched when the unit is heated up 5...

Страница 6: ...ntle pillar to stove 10 25 cm B Stove to 8 wide mantle 12 31 cm Stove must sit on a non combustible surface the width and depth of the insert Maintain sufficient clearances for operation service and m...

Страница 7: ...located on public property 7 feet 2 1m minimum M Clearance under verandah porch deck or balcony 24 inches 60 cm minimum A vent shall not terminate directly above a sidewalk or paved driveway which is...

Страница 8: ...peration of this heater when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in carbon monoxide CO poisoning and possibl...

Страница 9: ...ency Carefully follow the chimney manufacturer s instructions that accompany the liner kit Measure the height of the chimney before hand and purchase the appropriate kit Never attempt to over stretch...

Страница 10: ...arge build ups Do not pack down leave embers loose Place cast ember pieces between the door facing and the ember tray The curved edge is placed into the firebox Align the mitered corner edges DO NOT P...

Страница 11: ...11...

Страница 12: ...IONS 1 STOP Read the safety information above 2 Turn off all electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out an...

Страница 13: ...2 Turn off all electrical power to the appliance if service is to be performed 3 Flip burner switch to the off position 13...

Страница 14: ...ding upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a soft cloth Abrasive cleaners will damage the glass s...

Страница 15: ...11...

Страница 16: ...t dealer Burners will not light when valve and burner switch are both on Defective switch check switch connections jump wires at switch Defective thermopile check connections to valve check voltage ac...

Страница 17: ...ode ANSI Z223 1 UPON CONNECTION MARK APPROPRIATE FUEL TYPE ON CANADIAN STANDARDS ASSOCIATION RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL Manifold Pressure Tap Inlet Pressure Tap Mi...

Страница 18: ...purple wires CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing WARNING Electrical...

Страница 19: ...18 GAUGE 40 FEET 20 GAUGE 18 FEET 15...

Страница 20: ...12 mos 1 Turn the unit off and remove the log set 2 Remove the burner tray assembly by removing the screw on either side of the tray between the front and rear burners Lift the tray out Remove the br...

Страница 21: ...line from the pilot assembly and remove the pilot injector Re install the pilot new pilot injector BE CAREFUL WHEN TIGHTENING THE PILOT FITTING YOU COULD BREAK THE CERAMIC IGNITER ELECTRODE DO NOT reu...

Страница 22: ...nly thereafter The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is no way covered under warranty Your dealer shall make all claims under this...

Страница 23: ...del ___________________________________ Serial Number __________________ Date of Purchase __________ ________ ________ Date of Installation __________ ________ ________ ____ Natural Gas Nat ____ Propa...

Отзывы: