To instantly turn ON/OFF the specified output and set its state to ON/OFF when the system starts-up, please refer to the following
configuration methods.
Turn OFF output/Set
output start-up state
as OFF
SMS
SMS text message content:
ssss_Co:OFF
or
ssss_out-name:OFF
Value:
ssss
– 4-digit SMS password;
o
– output number, range - [1... 2];
out-name
– up to
16 characters output name.
Example:
1111_C2:OFF
Config
Tool
This operation may be carried out from the PC using the
GS-Configurator
software.
WEB
BROWSER
This operation may be remotely carried out from the PC using the web browser.
NOTE:
Output can be turned ON for a determined time period only when it is in OFF state.
NOTE:
Output can be turned OFF for a determined time period only when it is in ON state.
NOTE:
GS-Configurator
software allows to set only the output start-up state.
NOTE:
The administrator can control any output by SMS text message regardless of the output assigned to the administrator phone
number (see
ADMINISTRATOR PHONE NUMBERS
).
Содержание GS-500
Страница 1: ...GSM REMOTE CONTROL GS 500 USER MANUAL...
Страница 4: ...4 4 EN Manual GS 500_EN_2014 01...