background image

10

10

EN

Manual GS-500_EN_2014-01

4. GENERAL OPERATION

When a phone call is made to the phone number of the SIM card inserted in GS-500, the system will verify if the caller’s phone number exists 

in the memory. If the caller is one of the 5 administrators or the phone number belongs to one of the 500 database users, the system will 

reject the phone call, thus making the phone call free of charge, and open the gate. By ringing to GS-500 again, it will close the gate. If the 

phone number is not recognized, the system will reject the phone call and ignore it. The GSM switch-gate controller can also control your 

gate automatically in accordance with the scheduled time or by sending an SMS text message from the administrator’s phone number.
By connecting a sensor to one of the 3 inputs, the administrators can receive SMS text messages regarding the gates that failed to close 

during the set time period.

User/Admin  

CALL

7

5. CONFIGURATION METHODS

5.1.  SMS Text Messages

!!! In this installation manual the underscore character ”_” represents one space character. Every underscore character 

must be replaced by a single space character. There must be no spaces or other unnecessary characters at the beginning 

and at the end of the SMS text message.  

SMS

In order to configure and control the system by SMS text message, send the text command to the GS-500 system phone num-

ber from one of the preset administrator phone numbers. The structure of SMS text message consists of 4-digit SMS password 

(the default SMS password is 0000 – four zeros), the parameter and value. For some parameters the value does not apply e. g. 

STATUS. The variables are indicated in lower-case letters, while a valid parameter value range is indicated in brackets. 

5.2.  Programming button USR/PROG

With the button USR / PROG it is possible to add or delete phone numbers in a simple way. This option can not be used until 

the SMS password and at least one administrator is configured with SMS text messages or using the GS-Configurator soft-

ware via USB or GPRS. 

GS-Configurator

 is freeware and can be downloaded at: www.entrya.eu/en/download

5.3.  GS-Configurator

Config 

Tool

Software 

GS-Configurator

 is intended for GS-500 GSM remote control configuration via USB port locally. This software simpli-

fies system configuration process by allowing to use a personal computer in the process. Before starting to use

 GS-Configu-

rator

 software, please read the user guide provided in the software’s HELP section. 

GS-Configurator 

is freeware and can be downloaded at: www.entrya.eu/en/download

 

NOTE: 

  

GS-Configurator

 is secured with SMS password. The default SMS password is 

0000

 (see 

7. SMS PASSWORD

).

5.4.  Remote Configuration via Web Browser

WEB

BROWSER

The system comes equipped with a remote configuration feature allowing to configure the parameters via any available web 

browser. Before remotely connecting to GS-500 via GPRS connection, ensure that: 
• 

SIM card is inserted into the SIM CARD slot (see 

2.2. Main Unit, LED & Connector Functionality

). 

• 

Mobile internet service (GPRS) is enabled on the SIM card.

• 

GS-500 is powered up.

• 

Default SMS password is changed to a new 4-digit password (see 

7. SMS PASSWORD

). 

• 

Admin 1 phone number is set up (see 

8. ADMINISTRATOR PHONE NUMBERS

). 

• 

APN, user name and password are set up (see 

17. GPRS NETWORK SETTINGS

). 

GS-500

Содержание GS-500

Страница 1: ...GSM REMOTE CONTROL GS 500 USER MANUAL...

Страница 2: ...by an EN 60950 1 approved supply When connecting the power supply to the system switching the polarity terminal places does not have any affect External power supply can be connected to AC mains only...

Страница 3: ...ATABASE 17 10 1 User Validity and Access Restriction 20 11 OUTPUTS 23 11 1 Output Names 23 11 2 Output Control by Free of Charge Phone Call 24 11 3 Output Control by SMS Text Message 25 11 4 Output Co...

Страница 4: ...4 4 EN Manual GS 500_EN_2014 01...

Страница 5: ...specified The warranty is void if the system has been exposed to mechanical impact chemicals high humidity fluids corrosive and hazardous environments or force majeure factors Dear Customer Thank you...

Страница 6: ...ty limitation in accordance with a set deadline date time or number of rings to the system Output control restriction for users in accordance with the specified weekdays and time Event log of 1000 eve...

Страница 7: ...tton for setting user telephone numbers GSM g Green light emitting diode indicating GSM signal strength GSM r Red light emitting diode indicating SIM card status STATUS Bue light emitting diode indica...

Страница 8: ...g OUT1 OUT2 simultaneous Steady ON Excellent Flashing every 1 sec Programmation telephone numbers activating OUT1 Flashing 2 times per sec Programmation telephone numbers activating OUT2 2 3 Wiring Di...

Страница 9: ...e the default SMS password see 7 SMS PASSWORD for more details 9 Set the phone number for Admin 1 see 8 ADMINISTRATOR PHONE NUMBERS for more details 10 Set system date and time see 9 DATE AND TIME for...

Страница 10: ...eter and value For some parameters the value does not apply e g STATUS The variables are indicated in lower case letters while a valid parameter value range is indicated in brackets 5 2 Programming bu...

Страница 11: ...on may be remotely carried out from the PC using the web browser Establish remote connection for custom session duration SMS SMS text message content ssss_CONNECT TIMEOUT ses d Value ssss 4 digit new...

Страница 12: ...ocess 6 SYSTEM LANGUAGE The system comes equipped with a multiple languages for communication with the administrator by SMS text messages The default system language depends on the firmware which is b...

Страница 13: ...he alarm SMS text messages from the system s inputs see 14 1 Input Names and Alarm Notification GS 500 allows to assign output C1 output C2 or both outputs simultaneous control to a certain administra...

Страница 14: ...5 Example 1111_NR2 DEL Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web bro...

Страница 15: ...m start up and periodically by default every 30 days Via GSM network Once enabled the system automatically sends a date time request to the GSM operator This method is the most accurate synchronizatio...

Страница 16: ...r NOTE When setting up automatic date and time synchronization feature remotely you may wish to restart the system when done For more details please refer to 18 REMOTE SYSTEM RESTART NOTE The 0 value...

Страница 17: ...The blue STATUS LED light starts flashing every 2 sec for 10 minutes or until the USR PROG button is pressed again briefly 3 Dial the system s phone number before the 10 minute period expires using t...

Страница 18: ...Value ssss 4 digit SMS password ttteeellnnuumm up to 15 digits user phone number o output number range 1 output C1 2 output C2 3 both outputs user name up to 16 characters user name Example 1111_OUTPU...

Страница 19: ...d of deleting all users from the database please disable the user database using one of the following configuration methods Disable user database SMS SMS text message content ssss_DBM_OFF Value ssss 4...

Страница 20: ...111_NSCHED_John_5 ON Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web brows...

Страница 21: ...teeellnnuumm_ or ssss_EXPIRYTIME_user name_ Value ssss 4 digit SMS password ttteeellnnuumm up to 15 digits user phone number user name up to 16 characters user name Example 1111_EXPIRYTIME_44170911111...

Страница 22: ...ig Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser Remove ring counter fr...

Страница 23: ...11 1 Output Names The output s has a name that can be customized Typically the name specifies a device type connected to a determined output for example Gate The name can be used instead of output nu...

Страница 24: ...dministrators phone number For more details please refer to 11 4 Output Control Confirmation by Call Back Set output pulse duration SMS SMS text message content ssss_TIMER1 pl Value ssss 4 digit SMS p...

Страница 25: ...the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser Turn OFF output for time period SMS SMS text message content ssss_Co OFF hr mn sc...

Страница 26: ...11_C2 OFF Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser NOTE Out...

Страница 27: ...operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser Disable output control confirmation...

Страница 28: ...etails on how to set up the schedulers please refer to 12 SCHEDULERS Assign scheduler SMS SMS text message content ssss_OSHEDo_c ON Value ssss 4 digit SMS password o output number range 1 output C1 2...

Страница 29: ...11_SCHED4_AL OFF Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser E...

Страница 30: ...R This operation may be remotely carried out from the PC using the web browser Select Every Day SMS SMS text message content ssss_SCHEDc_AL ON Value ssss 4 digit SMS password c scheduler number range...

Страница 31: ...mwillsendthenotificationbySMStextmessagetotheadministrator phone number To clear the event log and or disable enable the notification regarding the full event log please refer to the following configu...

Страница 32: ...refer to the following configuration methods Enable FIFO type log Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remote...

Страница 33: ...ay be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser The system allows to view the current input st...

Страница 34: ...MS SMS text message content ssss_SMSALL ON Value ssss 4 digit SMS password Example 1111_SMSALL ON Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWS...

Страница 35: ...re WEB BROWSER This operation may be remotely carried out from the PC using the web browser Enable input SMS SMS text message content ssss_Zn ON Value ssss 4 digit SMS password n input number range 1...

Страница 36: ...e administrator phone number periodically The recommende period is once a day at 11 00 frequency 1 day time 11 The minimum period is every 1 hour frequency 0 days time 1 Typically this feature is used...

Страница 37: ...r phone number provided by the GSM operator must be set manually Set SMSC phone number SMS SMS text message content ssss_SMS_ ttteeellnnuumm Value ssss 4 digit SMS password ttteeellnnuumm up to 15 dig...

Страница 38: ...ntent ssss_SETGPRS Value ssss 4 digit SMS password Example 1111_SETGPRS Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be r...

Страница 39: ...Unnecessary space character might have been typed in SMS text message For product warranty repair service please contact your local retail store where this product was purchased If your problem could...

Страница 40: ...anced written authori zation by Entrya Technologies BVBA Entrya Technologies BVBA reserves the right to update or modify this document and or related products without a warning Hereby Entrya Technolog...

Отзывы: