background image

24

24

EN

Manual GS-500_EN_2014-01

11.2.  Output Control by Free of Charge Phone Call

To open or close the gate, dial the system’s phone number from any available user or administrator phone numbers (see 

10. USER PHONE 

NUMBER DATABASE

 and 

8. ADMINISTRATOR PHONE NUMBERS

 for phone number management). The phone call is free of charge as 

the system rejects it and turns ON the output (-s) for the preset time period (pulse; by default – 2 seconds) resulting in the gate opening or 

closing, depending on the current gate state. If there is more than one preset caller dialing to the system at the same time, the system will 

accept the incoming call from the caller who was the first to dial while other caller (-s) will be ignored.

The system supports a confirmation phone call to users/administrators phone number. For more details, please refer to 

11.4. Output 

Control Confirmation by Call Back

Set output pulse 

duration

SMS

SMS text message content:

ssss_TIMER1:pl 

Value: 

ssss

 – 4-digit SMS password; 

pl 

– pulse duration, range – [1... 10] seconds. 

Example: 

1111_TIMER1:8   

Config 

Tool

This operation may be carried out from the PC using the 

GS-Configurator

 software.

WEB

BROWSER

This operation may be remotely carried out from the PC using the web browser.

Set output pulse 

duration

SMS

SMS text message content:

ssss_TIMERo:pl

Value: 

ssss

 – 4-digit SMS password; o – output number, range [

1

 – output C1; 

– output 

C2]; 

pl

 – pulse duration, range – [1... 10] seconds.

Example

1111_TIMER2:4

Config 

Tool

This operation may be carried out from the PC using the 

GS-Configurator

 software.

WEB

BROWSER

This operation may be remotely carried out from the PC using the web browser.

NOTE: 

  

GS-Configurator

 software and remote configuration web interface allow to set the unlimited output pulse duration value.

Содержание GS-500

Страница 1: ...GSM REMOTE CONTROL GS 500 USER MANUAL...

Страница 2: ...by an EN 60950 1 approved supply When connecting the power supply to the system switching the polarity terminal places does not have any affect External power supply can be connected to AC mains only...

Страница 3: ...ATABASE 17 10 1 User Validity and Access Restriction 20 11 OUTPUTS 23 11 1 Output Names 23 11 2 Output Control by Free of Charge Phone Call 24 11 3 Output Control by SMS Text Message 25 11 4 Output Co...

Страница 4: ...4 4 EN Manual GS 500_EN_2014 01...

Страница 5: ...specified The warranty is void if the system has been exposed to mechanical impact chemicals high humidity fluids corrosive and hazardous environments or force majeure factors Dear Customer Thank you...

Страница 6: ...ty limitation in accordance with a set deadline date time or number of rings to the system Output control restriction for users in accordance with the specified weekdays and time Event log of 1000 eve...

Страница 7: ...tton for setting user telephone numbers GSM g Green light emitting diode indicating GSM signal strength GSM r Red light emitting diode indicating SIM card status STATUS Bue light emitting diode indica...

Страница 8: ...g OUT1 OUT2 simultaneous Steady ON Excellent Flashing every 1 sec Programmation telephone numbers activating OUT1 Flashing 2 times per sec Programmation telephone numbers activating OUT2 2 3 Wiring Di...

Страница 9: ...e the default SMS password see 7 SMS PASSWORD for more details 9 Set the phone number for Admin 1 see 8 ADMINISTRATOR PHONE NUMBERS for more details 10 Set system date and time see 9 DATE AND TIME for...

Страница 10: ...eter and value For some parameters the value does not apply e g STATUS The variables are indicated in lower case letters while a valid parameter value range is indicated in brackets 5 2 Programming bu...

Страница 11: ...on may be remotely carried out from the PC using the web browser Establish remote connection for custom session duration SMS SMS text message content ssss_CONNECT TIMEOUT ses d Value ssss 4 digit new...

Страница 12: ...ocess 6 SYSTEM LANGUAGE The system comes equipped with a multiple languages for communication with the administrator by SMS text messages The default system language depends on the firmware which is b...

Страница 13: ...he alarm SMS text messages from the system s inputs see 14 1 Input Names and Alarm Notification GS 500 allows to assign output C1 output C2 or both outputs simultaneous control to a certain administra...

Страница 14: ...5 Example 1111_NR2 DEL Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web bro...

Страница 15: ...m start up and periodically by default every 30 days Via GSM network Once enabled the system automatically sends a date time request to the GSM operator This method is the most accurate synchronizatio...

Страница 16: ...r NOTE When setting up automatic date and time synchronization feature remotely you may wish to restart the system when done For more details please refer to 18 REMOTE SYSTEM RESTART NOTE The 0 value...

Страница 17: ...The blue STATUS LED light starts flashing every 2 sec for 10 minutes or until the USR PROG button is pressed again briefly 3 Dial the system s phone number before the 10 minute period expires using t...

Страница 18: ...Value ssss 4 digit SMS password ttteeellnnuumm up to 15 digits user phone number o output number range 1 output C1 2 output C2 3 both outputs user name up to 16 characters user name Example 1111_OUTPU...

Страница 19: ...d of deleting all users from the database please disable the user database using one of the following configuration methods Disable user database SMS SMS text message content ssss_DBM_OFF Value ssss 4...

Страница 20: ...111_NSCHED_John_5 ON Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web brows...

Страница 21: ...teeellnnuumm_ or ssss_EXPIRYTIME_user name_ Value ssss 4 digit SMS password ttteeellnnuumm up to 15 digits user phone number user name up to 16 characters user name Example 1111_EXPIRYTIME_44170911111...

Страница 22: ...ig Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser Remove ring counter fr...

Страница 23: ...11 1 Output Names The output s has a name that can be customized Typically the name specifies a device type connected to a determined output for example Gate The name can be used instead of output nu...

Страница 24: ...dministrators phone number For more details please refer to 11 4 Output Control Confirmation by Call Back Set output pulse duration SMS SMS text message content ssss_TIMER1 pl Value ssss 4 digit SMS p...

Страница 25: ...the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser Turn OFF output for time period SMS SMS text message content ssss_Co OFF hr mn sc...

Страница 26: ...11_C2 OFF Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser NOTE Out...

Страница 27: ...operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser Disable output control confirmation...

Страница 28: ...etails on how to set up the schedulers please refer to 12 SCHEDULERS Assign scheduler SMS SMS text message content ssss_OSHEDo_c ON Value ssss 4 digit SMS password o output number range 1 output C1 2...

Страница 29: ...11_SCHED4_AL OFF Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser E...

Страница 30: ...R This operation may be remotely carried out from the PC using the web browser Select Every Day SMS SMS text message content ssss_SCHEDc_AL ON Value ssss 4 digit SMS password c scheduler number range...

Страница 31: ...mwillsendthenotificationbySMStextmessagetotheadministrator phone number To clear the event log and or disable enable the notification regarding the full event log please refer to the following configu...

Страница 32: ...refer to the following configuration methods Enable FIFO type log Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remote...

Страница 33: ...ay be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser The system allows to view the current input st...

Страница 34: ...MS SMS text message content ssss_SMSALL ON Value ssss 4 digit SMS password Example 1111_SMSALL ON Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWS...

Страница 35: ...re WEB BROWSER This operation may be remotely carried out from the PC using the web browser Enable input SMS SMS text message content ssss_Zn ON Value ssss 4 digit SMS password n input number range 1...

Страница 36: ...e administrator phone number periodically The recommende period is once a day at 11 00 frequency 1 day time 11 The minimum period is every 1 hour frequency 0 days time 1 Typically this feature is used...

Страница 37: ...r phone number provided by the GSM operator must be set manually Set SMSC phone number SMS SMS text message content ssss_SMS_ ttteeellnnuumm Value ssss 4 digit SMS password ttteeellnnuumm up to 15 dig...

Страница 38: ...ntent ssss_SETGPRS Value ssss 4 digit SMS password Example 1111_SETGPRS Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be r...

Страница 39: ...Unnecessary space character might have been typed in SMS text message For product warranty repair service please contact your local retail store where this product was purchased If your problem could...

Страница 40: ...anced written authori zation by Entrya Technologies BVBA Entrya Technologies BVBA reserves the right to update or modify this document and or related products without a warning Hereby Entrya Technolog...

Отзывы: