11.2. Output Control by Free of Charge Phone Call
To open or close the gate, dial the system’s phone number from any available user or administrator phone numbers (see
10. USER PHONE
NUMBER DATABASE
and
8. ADMINISTRATOR PHONE NUMBERS
for phone number management). The phone call is free of charge as
the system rejects it and turns ON the output (-s) for the preset time period (pulse; by default – 2 seconds) resulting in the gate opening or
closing, depending on the current gate state. If there is more than one preset caller dialing to the system at the same time, the system will
accept the incoming call from the caller who was the first to dial while other caller (-s) will be ignored.
The system supports a confirmation phone call to users/administrators phone number. For more details, please refer to
11.4. Output
Control Confirmation by Call Back
Set output pulse
duration
SMS
SMS text message content:
ssss_TIMER1:pl
Value:
ssss
– 4-digit SMS password;
pl
– pulse duration, range – [1... 10] seconds.
Example:
1111_TIMER1:8
Config
Tool
This operation may be carried out from the PC using the
GS-Configurator
software.
WEB
BROWSER
This operation may be remotely carried out from the PC using the web browser.
Set output pulse
duration
SMS
SMS text message content:
ssss_TIMERo:pl
Value:
ssss
– 4-digit SMS password; o – output number, range [
1
– output C1;
2
– output
C2];
pl
– pulse duration, range – [1... 10] seconds.
Example
:
1111_TIMER2:4
Config
Tool
This operation may be carried out from the PC using the
GS-Configurator
software.
WEB
BROWSER
This operation may be remotely carried out from the PC using the web browser.
NOTE:
GS-Configurator
software and remote configuration web interface allow to set the unlimited output pulse duration value.
Содержание GS-500
Страница 1: ...GSM REMOTE CONTROL GS 500 USER MANUAL...
Страница 4: ...4 4 EN Manual GS 500_EN_2014 01...