32
IP2085EN - 2014-09-01
3. Technical specifications
3.1 Operating instructions
Service class: 4 (minimum 10-5 years of working life with 100-200 cycles per day).
Applications: INTENSE (for apartment block, industrial and commercial entrances and car parks
with vehicle access or access for intense pedestrian use).
- Performance characteristics are to be understood as referring to the recommended weight (ap-
prox. 2/3 of maximum permissible weight). When used with the maximum permissible weight
a reduction in the above mentioned performance can be expected.
- Service class, running times, and the number of consecutive cycles are to be taken as merely
indicative, having been statistically determined under average operating conditions, and are
therefore not necessarily applicable to specific conditions of use.
QIK80EH
Power supply
230 V~ 50/60 Hz
Absorption
1.2 A
Torque
200 Nm
Insulation class
Class 1
Opening time
6÷12 s/90°
Closing time
6÷12 s/90°
Bar length (max)
7950 mm
Service class
4 - INTENSE
Intermittence
S2 = 50 min
S3 = 50%
Temperature
min -20° C max +55° C
Degree of protection
IP24D
Control panel
EL34
i
Every automatic system contains variable elements (friction, balancing and environ-
mental factors) that may substantially alter both the lifespan and performance of the
system or its components (including the spring). Tests have shown that the average
spring lifespan is around 100,000 cycles, so you are advised to check its state of wear
when this limit is reached. If there are clear signs of wear, or it is difficult to balance
the bar correctly, replace the spring.