40
IP2085EN - 2014-09-01
11. Limit switch adjustment
C
C
A
A
B
- Adjust the opening and closing position of the bar using the special screws [A].
- Adjust the opening and closing limit switches using the special cams [C] so that the switches
are activated approx. 3 mm before the mechanical stop [B].
1
D
D
F
E
3
2
12. Access to control panel
- Unscrew and remove the front screws [D].
- Pull the ring [E] and lift the cabinet cover [F].