42
IP2085EN - 2014-09-01
14. Routine maintenance plan
Perform the following operations and checks every 6 months, according to the intensity of use
of the automation.
Disconnect the 230 V~ power supply and batteries (if present):
- Clean and oil the levers and check the nuts and screws are all well tightened.
- Clean and grease the spring-post as shown in the figure.
- Check the electrical connections.
- Check that the manual release is operating correctly.
- Check that the bar is balanced correctly as shown on page 38.
- Check the state of wear of the mechanical parts, in particular the spring after about 100,000
work cycles.
Reconnect the 230V~ power supply and batteries (if present):
- Check that obstacle detection is operating correctly.
- Check that all control and safety functions are working correctly.
NB: For spare parts, see the spares price list.
i
i
Only use original spare parts for repairing or replacing products.
The installer must supply all information concerning the automatic, manual and emergency
operation of the motorised door or gate, and must provide the user with the operating
instructions.
The installer must prepare and keep a maintenance record showing all the routine and
extraordinary maintenance work carried out.