© Entrematic
Group AB 2015
14
6020031A — Commercial HVLS Fans
November 2016
HANG THE MOTOR
1. In the top hole of the down tube, install a supplied 6017448
3/8" dia. x 3-1/4" bolt and 6015118 nut loosely. Ensure
that the screw does not pinch or bind the power and
communication cables. See Fig 9.
2. Using the bolt installed in the previous step, hang the motor
and down tube assembly on the fan mount. Ensure that
the power and communication cables are free of binding
or pinching. See Fig 10.
3. Loosely install the second 6017448 3/8" dia. x 3-1/4" bolt
and nut in the bottom hole at the top of the down tube.
Ensure that the bolt does not pinch or bind the power and
communication cables. See Fig 11.
4. Using a spirit level, ensure that the down tube is plumb.
5. Tighten the 3/8" dia x 3-1/4" bolts to 20-28 ft-lbs.
INSTALLATION,
continued
Hang down tube
from fan mount
Down tube
Top hole
Bottom hole
Power and
communication cables
(to controller box)
Fig. 9
Fig. 10
Fig. 11