
set summertime recurring
2-18 Basic Configuration
Defaults
If
an
offset
is
not
specified,
none
will
be
applied.
Mode
Switch
command,
read
‐
write.
Example
This
example
shows
how
to
set
a
daylight
savings
time
start
date
of
April
4,
2004
at
2
a.m.
and
an
ending
date
of
October
31,
2004
at
2
a.m.
with
an
offset
time
of
one
hour:
G3(su)->set summertime date April 4 2004 02:00 October 31 2004 02:00 60
set summertime recurring
Use
this
command
to
configure
recurring
daylight
savings
time
settings.
These
settings
will
start
and
stop
daylight
savings
time
at
the
specified
day
of
the
month
and
hour
each
year
and
will
not
have
to
be
reset
annually.
Syntax
set summertime recurring
start_week start_day start_month start_hr_min end_week
end_day end_month end_hr_min
[
offset_minutes
]
Parameters
Defaults
If
an
offset
is
not
specified,
none
will
be
applied.
end_date
Specifies
the
day
of
the
month
to
end
daylight
savings
time.
end_year
Specifies
the
year
to
end
daylight
savings
time.
end_hr_min
Specifies
the
time
of
day
to
end
daylight
savings
time.
Format
is
hh:mm.
offset_minutes
(Optional)
Specifies
the
amount
of
time
in
minutes
to
offset
daylight
savings
time
from
the
non
‐
daylight
savings
time
system
setting.
Valid
values
are
1
‐
1440.
start_week
Specifies
the
week
of
the
month
to
restart
daylight
savings
time.
Valid
values
are:
first,
second,
third,
fourth,
and
last.
start_day
Specifies
the
day
of
the
week
to
restart
daylight
savings
time.
start_hr_min
Specifies
the
time
of
day
to
restart
daylight
savings
time.
Format
is
hh:mm.
end_week
Specifies
the
week
of
the
month
to
end
daylight
savings
time.
end_day
Specifies
the
day
of
the
week
to
end
daylight
savings
time.
end_hr_min
Specifies
the
time
of
day
to
end
daylight
savings
time.
Format
is
hh:mm.
offset_minutes
(Optional)
Specifies
the
amount
of
time
in
minutes
to
offset
daylight
savings
time
from
the
non
‐
daylight
savings
time
system
setting.
Valid
values
are
1
‐
1440.
Содержание G3G170-24
Страница 1: ...Enterasys G Series Ethernet Switch CLI Reference Firmware Version 1 00 xx P N 9034358 01...
Страница 2: ......
Страница 30: ...xxviii...
Страница 100: ...set ssl 2 56 Basic Configuration...
Страница 132: ...clear lldp port tx tlv 3 32 Discovery Protocol Configuration...
Страница 272: ...show spantree nonforwardingreason 6 52 Spanning Tree Configuration...
Страница 296: ...set garp timer 7 24 802 1Q VLAN Configuration...
Страница 384: ...clear nodealias config 11 34 Logging and Network Management...
Страница 438: ...Enabling Router Configuration Modes 14 4 Preparing for Router Mode...
Страница 514: ...show ip pimsm staticrp 16 56 IPv4 Routing Protocol Configuration...
Страница 524: ...traceroute ipv6 17 10 IPv6 Management...
Страница 602: ...show ipv6 ospf virtual link 19 46 OSPFv3 Configuration...