Mounting the Switch
2-4 Installation
Mounting the Switch
The
following
mounting
options
are
available
for
the
D2
switch.
Each
requires
that
you
purchase
a
separate
mounting
kit.
Proceed
to
mount
the
switch
in
your
desired
location
using
one
of
the
procedures
described
in
this
section:
•
Install
the
switch
in
the
rack
mount
kit
and
mount
the
switch
to
a
48.26
‐
centimeter
(19
‐
inch)
rack
or
other
secure
location,
as
described
in
Installing
the
Switch
into
a
Rack
.
•
Install
the
switch
in
a
table
mount
kit
and
mount
the
switch
under
a
table,
as
described
in
“
Installing
the
Switch
Under
a
Table
”
on
page 2
‐
10.
•
Install
the
switch
in
a
wall
mount
kit
and
mount
the
switch
on
a
wall,
as
described
in
“
Installing
the
Switch
on
a
Wall
”
on
page 2
‐
12.
•
Install
the
switch
in
a
lockbox
kit
and
mount
the
switch
on
a
wall,
as
described
in
“
Installing
the
Switch
in
the
Lockbox
and
Mounting
on
a
Wall
”
on
page 2
‐
15.
Installing the Switch into a Rack
The
D2
switch
can
be
single
or
dual
‐
mounted
in
a
standard
EIA
‐
310
‐
D
compliant
48.26
‐
centimeter
(19
‐
inch)
equipment
rack.
To
mount
one
or
two
switches
into
a
rack,
you
must
first
install
each
switch
into
a
rack
mount
kit
as
described
in
the
following
procedure.
You
must
provide
the
mounting
hardware
to
attach
the
assembled
kit
to
the
rack
rails.
Complete
the
following
steps
to
install
one
or
two
switches
in
the
rack
mount
kit:
1.
“
Positioning
and
Securing
One
or
Two
Switches
”
(page 2
‐
5)
2.
“
Installing
One
or
More
Power
Supplies
”
(page 2
‐
6)
3.
“
Mounting
the
Assembled
Kit
Into
a
Rack
”
(page 2
‐
9)
4.
“
Connecting
Power,
Console,
and
Network
Cables
”
(page 2
‐
9)
Caution:
Before installing the screws as described in this installation procedure, refer to “
Torque
Values
” on page A-3.
Precaución:
Antes de retirar los tornillos, tal como se describe en las instrucciones de instalación,
consulte “
Torque Values
” on page A-3.
Note:
The D2-PWR-POE is taller than one rack unit high. If you have installed one or more
D2-PWR-POE power supplies in the rack mount kit, ensure that your rack installation location
leaves at least one rack unit of free space above the mounted assembly kit.
Содержание D2G124-12
Страница 1: ...Enterasys D Series Ethernet Switch D2G124 12 D2G124 12P Hardware Installation Guide P N 9034395 02 ...
Страница 2: ......
Страница 12: ...x ...
Страница 16: ...xiv ...
Страница 20: ...Getting Help xviii About This Guide ...
Страница 26: ...PoE Power over Ethernet Support 1 6 Introduction ...
Страница 66: ...Resetting the D2 HIPWR POE 3 4 Troubleshooting ...
Страница 74: ...Regulatory Compliance A 8 Specifications ...
Страница 76: ...Index 2 ...