INVUE GV148 LIQUID CHEMICAL CONCENTRATION MONITOR
7
User Guide | Entegris, Inc.
DIMENSIONS
—
LED Status Codes
The monitor has 4 LEDs on the top of the cover
to help indicate visual status of the product.
LED
FUNCTION
#1
Processor heartbeat
#2
Communication in process
#3
Reserved
#4
Device error condition
Side View
21.7 mm
(0.86")
57.7 mm
(2.27")
3.6 mm
(0.14")
Front View
B
A
37.0 mm
(1.46")
128.8 mm (5.07")
141.1 mm (5.56")
C
Top View
32.5 mm (1.28")
2 x 4.1 mm (0.16")
2 x 7.1 mm (0.28")
18.3 mm (0.72")
LED #1
Recommended mounting
screws size: 1⁄4" or M6
67.3 mm
(2.65")
80.8 mm
(3.18")
Inlet /outlet
port connection
DIMENSIONS
A
B
C
1/4" Flaretek
®
tube fitting
114.6 mm (4.51")
33.0 mm (1.30")
111.0 mm (4.37")
3/8" Flaretek tube fitting
117.7 mm (4.64")
34.7 mm (1.37")
113.5 mm (4.47")
1/2" Flaretek tube fitting
120.9 mm (4.76")
36.3 mm (1.43")
119.6 mm (4.71")
3/4" Flaretek tube fitting
126.6 mm (4.99")
38.9 mm (1.53")
132.6 mm (5.22")
1" Flaretek tube fitting
126.6 mm (4.99")
38.9 mm (1.53")
154.9 mm (6.10")
1/2" PrimeLock
®
tube fitting
120.9 mm (4.76")
36.3 mm (1.43")
122.9 mm (4.84")
1" PrimeLock tube fitting
126.6 mm (4.99")
38.9 mm (1.53")
149.6 mm (5.89")
1/4" Pillar tube fitting
114.6 mm (4.51")
33.0 mm (1.30")
100.5 mm (3.96")
3/8" Pillar tube fitting
117.7 mm (4.64")
34.7 mm (1.37")
112.5 mm (4.43")
3/4" Pillar tube fitting
126.6 mm (4.99")
38.9 mm (1.53")
134.5 mm (5.29")