System Settings
Follow these steps to enter System Settings:
1.
Press
to display the Menu.
2.
Press
to System Settings. Press
to enter.
3.
Utilize keys 1, 2 and 3 to input the password (3482) and press
to enter the
category.
Engine Setup
Use the following to configure engine settings.
1.
Highlight Engine Type and press
to toggle between Electronic or Mechanical
engine types.
NOTE
: Selecting Electronic engine type will enable the Throttle menu to appear in
System Settings. The Throttle menu is disabled for Mechanical engine type.
2.
See the table below to configure remaining settings
Engine
Type
Configurable Settings
Electronic
DPF (Default: enabled)
SCR (Default: enabled)
ECU Source Address (Default: ALL)
Display Source Address (Default: 43)
Overspeed
o
Shutdown (Default)
% Over High Speed (Default: 5%)
Fault at High Speed (Default: 1890 RPM)
o
Warning
% Over High Speed
Fault at High Speed
o
Disabled
Machine Hours
o
Set Machine Hours
o
Clear Machine Hours