Section 78
00-02-0997 (web only)
2019-10-07
- 20 -
SPN
Available Options
695
(Eng Override
Control Mode)
0
– Override Disabled
1
– Speed Control
696 (Eng Req
Speed Control
Conditions)
0
– Transient Optimized for driveline disengaged and non-lockup
conditions*
1
– Stability Optimized for driveline disengaged and non-lockup
conditions*
2
– Stability Optimized for driveline engaged and/or in lockup
condition 1 (vehicle driveline)*
3
– Stability Optimized for driveline engaged and/or in lockup
condition 2 (PTO driveline)*
*(The above descriptions taken from SAE International document
J1939-71 May2012)
897 (Override
Control Mode
Priority)
0
– Highest Priority
1
– High Priority
2
– Medium Priority
3
– Low Priority
3349 (TSC1
Transmission
Rate)
0
– 1000 mS
1
– 750 mS
2
– 500 mS
3
– 250 mS
4
– 100 mS
5
– 50 mS
6
– 20 mS
7
– 10 mS
8.
To configure the JD Lockout, repeat steps 1
– 5 and Press
to
highlight the JD
Lockout selection then press
to Enable/Disable.
NOTE: The JD Lockout message allows the engine to regenerate when an external
interlock switch to the ECU is not present.