PROFInet Module
SINUS H
11
/
34
4
PROFInet Communication Related Keypad Parameters
To operate an Sinus H inverter using the PROFInet communication module, set DRV-06 (Cmd Source)
to [4 Fieldbus]. Set DRV-07 (Freq Ref Src) to [8 Fieldbus] to provide a frequency reference to the
inverter using the PROFInet communication module.
Code
Parameter Name
Default
Description
CNF
30 Option-1 Type
-
When the Sinus H PROFInet communication
module is installed, the module type “PROFInet” is
automatically detected and displayed.
Note 1)
DRV
06 Cmd Source
1 Fx/Rx-1
0
Keypad
1
Fx/Rx-1
2
Fx/Rx-2
3
Int 485
4
Fieldbus
5
UserSeqLink
07 Freq Ref Src
0 Keypad-1
0
Keypad-1
1
Keypad-2
2
V1
4
V2
5
I2
6
Int 485
8
FieldBus
9
UserSeqLink
12
Pulse
COM
06 FBus S/W Ver
-
-
09 FBus Led
-
-
10 opt para-1
0
IP - 1
11 opt para-2
0
IP - 2
12 opt para-3
0
IP - 3
13 opt para-4
0
IP - 4
14 opt para-5
0
Subnet Mask - 1
15 opt para-6
0
Subnet Mask - 2