Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring
20
2.4.4 Recommended Diameter of Wire (mm
2
)
model
Recommende
d output
current(A)
Output
voltage(V)
length≤
30m
length≤
60m
length≤
90m
length≤
120m
length≤
150m
length≤
180m
length≤
210m
BS-550-L
3
1HP 230V
0.75
1
1.5
2.5
2.5
2.5
4
BS-750-L
5
3HP 220V
0.75
1.5
2.5
2.5
4
4
4
BS-1100-L
6
3HP 220V
1
1.5
2.5
4
4
4
6
BS-1500-L
7
3HP 220V
1
2.5
2.5
4
4
6
6
BS-2200-L
11
3HP 220V
1.5
2.5
2.5
6
6
6
6
BS-3000
8
3HP 380V
1.5
2.5
2.5
6
6
6
6
BS-4000
10
3HP 380V
1.5
2.5
2.5
6
6
6
6
BS-5500
13
3HP 380V
2.5
2.5
4
6
6
6
6
BS-7500
18
3HP 380V
2.5
4
6
6
10
10
BS-9200
21
3HP 380V
4
4
6
10
10
10
BS-11K
24
3HP 380V
4
6
10
10
10
16
BS-13K
28
3HP 380V
6
6
10
10
10
10
BS-15K
30
3HP 380V
6
6
10
10
16
16
BS-18K5
39
3HP 380V
6
10
10
16
16
25
BS-22K
45
3HP 380V
10
16
16
25
25
Units: mm
2
Notice: the environment temperature of the above recommended wire dimension is ≤50°C.
Notice: large-power wall-mounted model uses multiple-channel DC input. The dimension
of DC wire of each channel shall be selected according to the above table.