1.System Introduction 

 

 

The Enersound CU-12 Control Unit works as a main unit to provide power, input and output interface, 
and control for up to 11 dual interpreter consoles. It allows up to 22 interpreters to perform simultaneous 
interpretation for a maximum of 11 target languages plus one floor (original) language. 

 

The  Enersound  IC-12  is  a  12-channel  dual  interpreter  console  with  relay  capabilities.  It  allows  two 

interpreters  to  work  together.  Interpreters  can  choose  either  floor  channel to  listen  to  the  speaker  and 

perform direct interpretation or choose the relay mode when the interpreter does not understand the floor 

language  and  listen to  the  interpretation  from  a  different booth  in  a  language  that  this  interpreter  can 

understand.   

 

The IC-12 also allows interpreters to select the outgoing channel depending on the language they are 

interpreting  into  (two-way  interpretation),  switch  on/  off  and  mute  their  microphone,  and  control  the 

headphone volume.  

 

The system features a security lock that prevents two interpreters to select the same outgoing channel at 

the same time.    

 

The product is a professional, easy plug and play, stand-alone system that can be integrated with most 

infrared (IR) or radio frequency (RF) language discussion systems.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание CU-12

Страница 1: ...Control Unit CU 12 Interpreter Console IC 12 INTERPRETATION System User Manual...

Страница 2: ...edical device consult your physician or the manufacturer of your pacemaker or other medical device Using this product at a loud volume or over a prolonged period of time can lead to permanent hearing...

Страница 3: ...gnitude to constitute a risk of electric shock The exclamation mark within an equilateral triangle is intended to alert the user of the presence of important operating and maintenance servicing instru...

Страница 4: ...preter Console IC 12 4 5 3 System Installation 6 7 4 System Operation 8 9 4 1 Open Mode 8 9 4 2 Lock Mode 9 5 Technical Data 10 6 System Mounting Instructions 11 7 Limited Warranty Statement 11 Remark...

Страница 5: ...form direct interpretation or choose the relay mode when the interpreter does not understand the floor language and listen to the interpretation from a different booth in a language that this interpre...

Страница 6: ...the signal level of the corresponding channel 5 Power On Indicator Red 6 Power Switch Select I to turn on the system and select 0 to turn it off 7 Power Supply Socket 3 Prong with built in fuse T2A 25...

Страница 7: ...d to an output of a conference system or PA as the floor signal of the interpretation system 16 Alarm Sound Input This1 4 inch 6 3mm jack unbalanced inputallows to connect audiofrom an emergency or al...

Страница 8: ...e ON position 20 Outgoing Channel Selector In OPEN Mode it allows the interpreter to select the desired outgoing channel as long as it is not occupied by another booth When a channel is selected the c...

Страница 9: ...at any time as long as it is not occupied In LOCK mode the outgoing channel is pre set Only one outgoing channel will be programmed per console setting procedure refer to System Installation and Syst...

Страница 10: ...le and the socket to the INPUT of the next Interpreter Console 2 Follow the same procedure until all interpreter consoles are connected A maximum of 11 interpreter units can be connected allowing up t...

Страница 11: ...r language 7 Plug the control unit s line cord into an AC power outlet 100 to 240 V 50 60Hz and turn on the control unit 8 In Open Mode make sure the Mode switch is in open position and the Set switch...

Страница 12: ...ing interpreter consoles in open mode with direct and relay interpretation Note It is always necessary to utilize a PA System Sound System in conjunction with the interpretation system so that any spe...

Страница 13: ...sten to the original floor audio therefore her FLOOR Channel Key should be selected 4 2 Lock Mode This mode is used in special cases when there is one way interpretation i e the interpreter will alway...

Страница 14: ...rl Shorted to GND Slow output 12V 1sec Pulse CH0 CH11 output level 180mV 20mV CH0 balance output level 85mV GND85mV 10mV REC OUT output level 170mV 15mV REC IN input level 25dB 2dB Protocol RS 485 Dim...

Страница 15: ...cal expenses or any direct incidental or consequential damages caused by any use defect failure or malfunction of the product whether a claim for such damages is based upon warranty contract tort or o...

Страница 16: ...CU 12 IC 12 Version 2 1...

Отзывы: