About this Manual  
 

Read this user manual carefully before installing and operating your Enersound Interpretation System. Use 
the equipment only as described to avoid accidental injury, damage or hearing impairment. Also, read safety 
warnings carefully. Keep this manual for future reference. If you give this system to someone else, 
remember to include this manual. 
 

Safety Precautions 
 

 

Make all connections before plugging the unit into an AC power outlet. 

 

Hot swapping is prohibited: Never connect or disconnect any cables with the system turned on, especially 
the 25-pin cables. Always turn off the system before plugging or unplugging interpreter units, 
microphones or cables so as not to damage the system.  

 

Do not leave the devices in places with high temperatures or high humidity. 

 

Do not handle the power cord with wet hands. 

 

Keep the devices away from fire and heat sources. 

 

Do not place the equipment on an unstable stand. Use appropriate or original packaging provided by the 
manufacturer before transporting the system to avoid damaging or breaking it. 

 

Adequate ventilation is beneficial for better performance and storage of the equipment. 

 

Keep the system out of the reach of children. 

 

The CU-12 must be connected to ground via the power cable for safety reasons and to ensure the audio 
performance of the system.  

 

Do not open the CU-12 and/or interpreter consoles. There are no user serviceable parts inside. 

 

Before using this product with a pacemaker or other medical device, consult your physician or the 
manufacturer of your pacemaker or other medical device. 

 

Using this product at a loud volume or over a prolonged period of time can lead to permanent hearing 
damage. 

 

Reduce the volume to its lowest setting before use. 

 

When using XLR microphone inputs, connect only microphones that can accept 48Volt Phantom power; 
otherwise, there may be risk of damage, injury, fire or explosion. 

 

When using a mobile phone near this product, noise may be produced, but this is not a malfunction. Keep 
mobile phones as far away as possible from the product. 

 

To clean, be sure to first switch off and unplug the CU-12 from the power outlet, then wipe with a dry 
cloth. When extremely dirty, use a soft cloth dampened in neutral detergent. Never use benzene, thinner 
or chemically-treated towels, which may damage the product’s finish. 

 

Only use Enersound approved cables to connect the system. Do not use any accessory not recommended 
by the manufacturer. 

 

A maximum of 11 sets of IC-12 can be connected in one system. The cumulative cable length should not 
exceed 70 meters. For specific requirements, please contact Enersound at 1 800-644-5090 or 
[email protected]

 

Service must be performed by authorized technicians only. For service, please contact your local 
distributor or Enersound at 1 800-644-5090 or [email protected].  

 

Turn off the power supply and unplug the equipment from the power supply in case the equipment is not 
in use for a long time. 

 
Please register the product within 30 days of purchase. To Register Product: 
1) Go to www.enersound.com/registration.html 
2) Follow instructions to complete the online product registration form.  

Содержание CU-12

Страница 1: ...Control Unit CU 12 Interpreter Console IC 12 INTERPRETATION System User Manual...

Страница 2: ...edical device consult your physician or the manufacturer of your pacemaker or other medical device Using this product at a loud volume or over a prolonged period of time can lead to permanent hearing...

Страница 3: ...gnitude to constitute a risk of electric shock The exclamation mark within an equilateral triangle is intended to alert the user of the presence of important operating and maintenance servicing instru...

Страница 4: ...preter Console IC 12 4 5 3 System Installation 6 7 4 System Operation 8 9 4 1 Open Mode 8 9 4 2 Lock Mode 9 5 Technical Data 10 6 System Mounting Instructions 11 7 Limited Warranty Statement 11 Remark...

Страница 5: ...form direct interpretation or choose the relay mode when the interpreter does not understand the floor language and listen to the interpretation from a different booth in a language that this interpre...

Страница 6: ...the signal level of the corresponding channel 5 Power On Indicator Red 6 Power Switch Select I to turn on the system and select 0 to turn it off 7 Power Supply Socket 3 Prong with built in fuse T2A 25...

Страница 7: ...d to an output of a conference system or PA as the floor signal of the interpretation system 16 Alarm Sound Input This1 4 inch 6 3mm jack unbalanced inputallows to connect audiofrom an emergency or al...

Страница 8: ...e ON position 20 Outgoing Channel Selector In OPEN Mode it allows the interpreter to select the desired outgoing channel as long as it is not occupied by another booth When a channel is selected the c...

Страница 9: ...at any time as long as it is not occupied In LOCK mode the outgoing channel is pre set Only one outgoing channel will be programmed per console setting procedure refer to System Installation and Syst...

Страница 10: ...le and the socket to the INPUT of the next Interpreter Console 2 Follow the same procedure until all interpreter consoles are connected A maximum of 11 interpreter units can be connected allowing up t...

Страница 11: ...r language 7 Plug the control unit s line cord into an AC power outlet 100 to 240 V 50 60Hz and turn on the control unit 8 In Open Mode make sure the Mode switch is in open position and the Set switch...

Страница 12: ...ing interpreter consoles in open mode with direct and relay interpretation Note It is always necessary to utilize a PA System Sound System in conjunction with the interpretation system so that any spe...

Страница 13: ...sten to the original floor audio therefore her FLOOR Channel Key should be selected 4 2 Lock Mode This mode is used in special cases when there is one way interpretation i e the interpreter will alway...

Страница 14: ...rl Shorted to GND Slow output 12V 1sec Pulse CH0 CH11 output level 180mV 20mV CH0 balance output level 85mV GND85mV 10mV REC OUT output level 170mV 15mV REC IN input level 25dB 2dB Protocol RS 485 Dim...

Страница 15: ...cal expenses or any direct incidental or consequential damages caused by any use defect failure or malfunction of the product whether a claim for such damages is based upon warranty contract tort or o...

Страница 16: ...CU 12 IC 12 Version 2 1...

Отзывы: