![Enersound CU-12 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/enersound/cu-12/cu-12_user-manual_2411398014.webp)
5. Technical Data
System environmental Conditions
Transport Temp
-40○C ~ +70○C
Operational Temp.
0
○
C ~ +45
○
C Max.
Relative humidity
<95%
Control Unit CU-12 Technical Data
Power supply
110-240Vac
System consumption
90W
DC power output
+15V/0.3A x12
D-SUB power output
DC+15V/2A
Line In sensitivity
-30dB±2dB LEVEL VR at MAX.
Alarm In sensitivity
-20dB±2dB
MIC In sensitivity
-51dB±2dB Gain VR at MAX.
Alarm Ctrl
Shorted to GND
Slow output
+12V, 1sec Pulse.
CH0~CH11 output level
180mV±20mV
CH0 balance output level
85mV-GND85mV±10mV
REC OUT output level
170mV±15mV
REC IN input level
-25dB±2dB
Protocol
RS-485
Dimension (LxWxH)
421x213x44mm
Color
Gray
Weight
2.65Kg.
Interpreter Console IC-12 Technical Data
Unit power
DC+15V
Unit power consumption
100mA±10mA
MIC sensitivity
-45dB±2dB
XLR MIC sensitivity
-45dB±2dB
Earphone max output level
30mW+30mW at 32Ω,
REC OUT output level
140mV±10mV
Protocol
RS-485
In/Out interface
D-Sub 25P plug and socket
Dimension (LxWxH)
330x206x57mm
Color
Gray
Weight
2.5Kg
10