9.5.8 - REPLACING THE FUEL SEPARATOR CARTRIDGE
Replacing the fuel separator cartridge
Carry out the procedure below to change the fuel filter
(
every 500 hours
):
1. Stop the engine and wait for it to cool down.
2. Turn off the fuel supply by closing the valve (A).
3. Disconnect the electric cables.
4. Place a suitable collection receptacle.
5. Loosen the vent screw (C) and the drain valve (B).
6. Turn the bowl (D) towards the left, unscrew it and
then remove it.
7.
Remove the float ring from the bowl (D).
8. Clean the inside of the bowl (D).
9. Install a new cartridge.
10.
Reinstall float ring in the bowl (D).
11. Check the condition of the O-rings, replace if
necessary.
12. Screw the bowl (D) back on with a torque of 27 - 33
Nm.
13. Close the drain valve (B) with a torque of 1 - 2 Nm.
14. Open the fuel supply valve (A).
15. Check for leaks.
A
B
C
D
DANGER:
•
This operation must be carried out with engine off.
•
Because the fuel is highly inflammable, do not get close to it with naked flames and
do not smoke whilst performing this operation.
•
Clean the area soiled by the fuel immediately.
•
Wear protective clothing when carrying out this operation.