59
© 2017 Energreen Srl
Professional machinery
Malfunctions
Causes
Measures
The charge indicator light of the
alternator does not turn on when the
engine is stopped (ignition key on
"I").
Defective lamp.
Replace (*)
Defective cables.
Check and repair (*)
(*) If the fault or the reason for it is not indicated in the list of faults shown in tables below, contact ENERGREEN in order for repairs to be carried out.
6.9.4 - HYDRAULIC SYSTEM
Malfunctions
Causes
Measures
The pump emits a strange noise.
Defective pump
Repair or replace (*)
Insufficient oil in the tank
Restore the level
The equipment work at low speed.
Defective pump
Repair or replace (*)
Maximum pressure valve out of
calibration or not closed due to
impurities.
Calibrate or replace (*)
Dirty unloading filter
Replace the cartridge
(*) If the fault or the reason for it is not indicated in the list of faults shown in tables below, contact ENERGREEN in order for repairs to be carried out.
6.9.5 - TRANSMITTER UNIT (REMOTE CONTROL)
Malfunctions
Causes
Measures
The green LED does not come on
when the START button is pressed
even if both the battery and the
S-KEY are in.
The battery is flat
Exchange the battery with one that is
charged.
The green LED flashes rapidly.
The radio electric connection
is absent.
Bring the transmitter unit towards the
receiver unit.
The red LED lights up for 2 seconds
and then the unit goes out.
The transmitter unit is not
working properly.
Carry out the address storage procedure.
Contact ENERGREEN customer care
The red LED flashes once on start
up.
The STOP button is on or it is
broken.
Remove the STOP BUTTON If this signal
persists contact ENERGREEN customer
care.
The red LED flashes twice on start
up.
At least one of the actuators
relative to the digital
commands and the SAFETY
is active or it is broken.
Move the actuators into the rest position. If
this signal persists contact ENERGREEN
customer care.
The red LED flashes three times on
start up.
The battery is flat
Exchange the battery with one that is
charged.
The red LED flashes four times on
start up.
At least one of the actuators
relative to the analogue
commands and the SAFETY
is active or it is broken
Move the actuators into the rest position. If
this signal persists contact ENERGREEN
customer care.
If the fault or the reason for it is not indicated in the list of faults shown in tables below, contact ENERGREEN in order for repairs to be carried out.
Содержание RoboMAX
Страница 2: ......
Страница 104: ...96 2017 Energreen Srl Professional machinery 12 NOTES...