Operation
Starting the generator
Version: May 2011
ESE 808 / 1308 / 1408 DBG ES DU PLEX SILENT
38
alternatively upon failure of the electrical start:
(the hand start can be achieved more easily by two people)
1. Covering hood
(Fig. 3-1-(1))
completely open.
2. Pull on the manually-operated choke
(Fig. 4-1-(2
))
(completely for a cold engine / appropriately less for
a warm engine) and hold firmly.
3. For model ESE 1308 / 1408 the manual fuel pump
(see Fig. 4-2-(1))
must be actuated 3x.
4. Set the START-STOP switch
(Fig. 4-1-(1))
to position "1“.
5. Advance engine at the handgrip of the reversing starter
(Fig. 4-1-(3))
.
Support oneself with one hand on the device grip in order to
simplify advancing the engine.
The engine starts.
6. Bring the choke into the basic position.
The engine has started.
CAUTION!
Generators with remote controls are fitted with an
automatic choke. It is not necessary to use the manual
choke.
Fig. 4-2: Emergency start
HAND START
NOTE
Содержание ESE 1308 DBG ES DUPLEX SILENT
Страница 7: ...Table of Contents Version May 2011 ESE 808 1308 1408 DBG ES DUPLEX SILENT 7...
Страница 11: ...General information Safety symbols Version May 2011 ESE 808 1308 1408 DBG ES DUPLEX SILENT 11 Notes...
Страница 16: ...General Safety Regulations Intended use Version May 2011 ESE 808 1308 1408 DBG ES DUPLEX SILENT 16...
Страница 42: ...Operation Putting the generator out of service Version May 2011 ESE 808 1308 1408 DBG ES DUPLEX SILENT 42 Notes...
Страница 75: ...Troubleshooting Version May 2011 ESE 808 1308 1408 DBG ES DUPLEX SILENT 75 Notes...
Страница 79: ...Replacement parts Sound absorbing hood Version May 2011 ESE 808 1308 1408 DBG ES DUPLEX SILENT 79 Notes...