Accessories
Waterpilot FMX167
20
Hauser
10.4
TMT181 temperature head transmitter (4 to 20 mA)
• 2-wire temperature head transmitter, configured for a measuring range from
–20 to +80 °C (–4 to +176 °F). This setting offers a temperature range of 100K which can
be easily mapped. Please note that the Pt100 resistance thermometer is designed for a
temperature range from –10 to +70 °C (+14 to +158 °F), (
11).
• Order number: 52008794
10.5
Extension cable mounting screw
• Hauser offers extension cable mounting screws to ease FMX167 mounting and
to seal the measuring aperture (
• Material: 304 (1.4301)
• Order number for extension cable mounting screw:
– 52008264 (G 1½" A)
– 52009311 (NPT 1½")
10.6
Terminals
• Four terminals in strip for FMX21 terminal box, suitable for wire cross-sections: 0.08 to
2.5 mm
(28...14 AWG)
• Order number: 52008938
10.7
Cable marking
To make installation easier, Hauser marks the customer-specific length on the
extension cable, see Technical Information TI00351P/00/EN, "Ordering information"
section.
A0018792
A
Cable marking
B
Cable marking tolerance
• Cable marking tolerance (distance to the
lower end of the cable probe):
Cable length < 5 m (16 ft): ±17.5 mm
(0.69 in)
Cable length > 5 m (16 ft): ±0,2 %
• Material: PET, Adhesive: acrylic
• Immunity to temperature change:
–30 to +100 °C (–22 to 212 °F)
NOTICE
The mark is only for installation purposes.
‣
It must be thoroughly removed without
trace in the case of devices with drinking
water approval. The extension cable must
not be damaged in the process.
WARNING
!
Explosion hazard!
‣
Not for use in hazardous areas.
B
A
Содержание Waterpilot FMX167
Страница 23: ...Waterpilot FMX167 Endress Hauser 23...