Mounting
Waterpilot FMX167
10
Hauser
4.3
Mounting with an extension cable mounting screw
A0018794
Illustrated with thread G 1½". Dimensions in mm (in)
1
Extension cable
2
Cover mounting screw
3
Sealing ring
4
Clamping sleeves
5
Mounting screw adapter
6
Top edge of clamping sleeve
7
Required length of extension cable and probe before assembly
8
After assembly, item 7 is located next to the mounting screw with
G 1½" thread: height of sealing surface of the adapter or NPT 1½" thread height of thread run-out of adapter
If you want to lower the level probe to a certain depth, place the top edge of the
clamping sleeve 40 mm (1.57 in) higher than the required depth. Then push the
extension cable and the clamping sleeve into the adapter as described in Step 6 in the
following section.
4.3.1
Mounting extension cable mounting screw with G 1½" or
NPT 1½" thread:
Mark the desired length of the extension cable on the extension cable.
Insert the probe through the measuring aperture and carefully lower on the extension
cable. Fix the extension cable to prevent it from slipping.
Push the adapter (item 5) over the extension cable and screw it tightly into the
measuring aperture.
Push the sealing ring (item 3) and cover (item 2) onto the cable from above. Press the
sealing ring into the cover.
Place the clamping sleeve (item 4) around the extension cable at the mark (item 1) in
accordance with step 1.
Push the extension cable with the clamping sleeve (item 4) into the adapter (item 5).
Push the cover (item 2) and sealing ring (item 3) onto the adapter (item 5) and screw
tightly to the adapter.
Reverse the sequence of steps to remove the extension cable mounting screw.
CAUTION
!
Risk of injury
‣
Application in unpressurized containers only.
+40
()
+1.57
1
6
8
7
2
3
4
5
36
41