Mounting the terminal box
The optional ° is mounted with four screws (M4). For the dimensions of the terminal box,
please refer to Technical Information TI00351P/00/EN for the Waterpilot, "Mechanical
construction" section (
see also: www.endress.com
Select Country
Download
Media Type: Documentation).
4.5
Mounting the TMT181 temperature head transmitter
A0018806
Temperature head transmitter with terminal box
1
Mounting screws
2
Mounting springs
3
TMT181 temperature head transmitter
4
Circlips
5
Terminal box
Only open the terminal box with a screwdriver.
4.5.1
Mounting the temperature head transmitter
Guide the mounting screws (item 1) with the mounting springs (item 2) through the
guide holes of the temperature head transmitter (item 3).
Fix the mounting screws with the circlips (item 4). Circlips, mounting screws and
springs are included in the scope of delivery for the temperature head transmitter.
Screw the temperature head transmitter into the field housing tightly.
(Max. width of screwdriver blade 6 mm (0.24 in))
NOTICE
Prevent damage to the temperature head transmitter.
‣
Do not tighten the mounting screw too tightly.