Stamoclean CAT430
Installation
Hauser
9
3.3
Installation instructions
To mount the individual modules, proceed as follows:
1.
Mount the filter element holders.
2.
Mount the guide tube, retaining slide and filtrate line.
3.
Mount the filter elements.
4.
Mount the control box.
5.
Connect the sample lines to the measuring devices.
"
Caution!
• Before beginning installation, make sure that there are no pipes, stirrers or other equipment up to
approx. 1 m (3.3 ft) below the surface of the water at the intended point of installation. This
equipment can damage the filter elements.
• Check that there is sufficient space between the filter unit and the rim of the basin. This applies
especially to filter units with numerous filter elements.
If there is not sufficient space, a special holder must be used.
• The flow rate at the point of installation must not be over 2 m/s (6.6 ft/s).
3.3.1
Mounting the filter element holders
!
Note!
Please, order filter element holders separately. See "Accessories".
a0007158
Fig. 3:
Holder for open channel, side view
a0007157
Fig. 4:
Holder for basin, side view
100
(3.94)
525 (20.7)
75 (2.95)
150
(5.91)
200
(7.87)
100
(3.94)
1500
/
1800
(59.1
/
70.9)
108
(4.25)
30 (1.18)
120
(4.72)
500
(19.7)
400 (15.8)
160
(6.30)
12
(0.47)
mm (inch)
30 (1.18)
120
(4.72)
500
(19.7)
400
(15.8)
200
(7.87)
100
(3.94)
1500
/
1800
(59.1
/
70.9)
108
(4.25)
160
(6.30)
12
(0.47)