![Endress+Hauser Stamoclean CAT430 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/endress-hauser/stamoclean-cat430/stamoclean-cat430_operating-instructions-manual_2407534017.webp)
Stamoclean CAT430
Wiring
Hauser
17
For power supply:
You have to connect terminals 15, 20 and 24.
All other connections have been made at the factory.
For electric band heater connection:
You have also to connect terminals 8, 14 and 23 if using an electric band heater for the sample line
to the analyzer (discharge side of the pump).
The heater for the hose to the suction side is included in versions CAT430-****B**. The
connections (terminals 1, 6 and 25) have been made at the factory.
a0007147
Fig. 14:
Control unit terminal block (inside the control box)
a
b
Control
Thermal switch 24 V
c
d
Filtrate hose heater 24 V
(suction side of the pump)
Pump
e
f
Electric band heater
(discharge side of the pump)
Housing heater
T
1)
1) T
=
terminal
Assignment
T
1
Assignment
T
1
Assignment
1
24 V to hose heater
10
Phase L housing heater
19
not connected
2
24 V from thermal switch
11
Phase L to control 6
20
Phase L mains supply
3
not connected
12
Phase L to control 2
21
not connected
4
not connected
13
Zero conductor (as required)
22
not connected
5
24 V to thermal switch
14
Electric band heater zero cond.
23
PE electric band heater
6
24 V to hose heater
15
Mains supply zero conductor
24
PE mains supply
7
Phase L from relay
16
Housing heater zero conductor
25
PE housing heater
8
Phase L electric band heater
17
Pump zero conductor
26
not connected
9
Phase L pump contin. operation
18
Control zero conductor
23
24
7
8
9
13 14 15
3
4
21 22
19
20
1
2
3
4
5
6
PROG. RESET
N
L
PE
25 26
16 17 18
10 11 12
1
2
5
6
a
b
c
f
e
d
L
N
PE