Proline Promag 55S
24
Hauser
Pressure loss
• No pressure loss if the sensor is installed in a pipe of the same nominal diameter.
• Pressure losses for configurations incorporating adapters according to DIN EN 545
→
ä
17.
Flow rate characteristic values - Promag S (US units)
Nominal
diameter
Recommended flow rate
Factory settings
[inch]
min./max. full scale value
(v
≈
1.0 or 33 ft/s)
Full scale value
(v
≈
8.2 ft/s)
Pulse value
(
≈
2 pulse/s)
Low flow cut off
(v
≈
0.1 ft/s)
½"
1.0 to 27 gal/min
6 gal/min
0.05 gal
0.10 gal/min
1"
2.5 to 80 gal/min
18 gal/min
0.20 gal
0.25 gal/min
1¼"
4 to 130 gal/min
30 gal/min
0.20 gal
0.50 gal/min
1½"
7 to 190 gal/min
50 gal/min
0.50 gal
0.75 gal/min
2"
10 to 300 gal/min
75 gal/min
0.50 gal
1.25 gal/min
2½"
16 to 500 gal/min
130 gal/min
1 gal
2.0 gal/min
3"
24 to 800 gal/min
200 gal/min
2 gal
2.5 gal/min
4"
40 to 1250 gal/min
300 gal/min
2 gal
4.0 gal/min
5"
60 to 1950 gal/min
450 gal/min
5 gal
7.0 gal/min
6"
90 to 2650 gal/min
600 gal/min
5 gal
12 gal/min
8"
155 to 4850 gal/min
1200 gal/min
10 gal
15 gal/min
10"
250 to 7500 gal/min
1500 gal/min
15 gal
30 gal/min
12"
350 to 10600 gal/min
2400 gal/min
25 gal
45 gal/min
14"
500 to 15000 gal/min
3600 gal/min
30 gal
60 gal/min
16"
600 to 19000 gal/min
4800 gal/min
50 gal
60 gal/min
18"
800 to 24000 gal/min
6000 gal/min
50 gal
90 gal/min
20"
1000 to 30000 gal/min
7500 gal/min
75 gal
120 gal/min
24"
1400 to 44 000 gal/min
10500 gal/min
100 gal
180 gal/min
Содержание Proline Promag 55S
Страница 47: ...Proline Promag 55S Endress Hauser 47...