Nominal diameter and
flow rate
The diameter of the pipe and the flow rate determine the nominal diameter of the sensor. The optimum flow
velocity is between 2 and 3 m/s (6 to 10 ft/s). The flow velocity (v), moreover, has to be matched to the phy-
sical properties of the fluid:
• v < 2 m/s (< 6 ft/s): for abrasive fluids where solids do not cause sedimentation (e.g. lime milk)
• v > 2 m/s (> 6 ft/s): for fluids producing build-up (e.g. wastewater sludge)
• v > 2 m/s (> 6 ft/s): for abrasive sludge with a high sand or stone content and where the solids easily cause
sedimentation (e.g. ore slurry)
!
Note!
Flow velocity can be increased, if necessary, by reducing the nominal diameter of the sensor through the use
of adapters
→
ä
17.
Flow rate characteristic values - Promag S (SI units)
Nominal
diameter
Recommended flow rate
Factory settings
[mm]
min./max. full scale value
(v
≈
0.3 or 10 m/s)
Full scale value
(v
≈
2.5 m/s)
Pulse value
(
≈
2 pulse/s)
Low flow cut off
(v
≈
0.04 m/s)
15
4 to 100 dm
3
/min
25 dm
3
/min
0.20 dm
3
0.5 dm
3
/min
25
9 to 300 dm
3
/min
75 dm
3
/min
0.50 dm
3
1 dm
3
/min
32
15 to 500 dm
3
/min
125 dm
3
/min
1.00 dm
3
2 dm
3
/min
40
25 to 700 dm
3
/min
200 dm
3
/min
1.50 dm
3
3 dm
3
/min
50
35 to 1100 dm
3
/min
300 dm
3
/min
2.50 dm
3
5 dm
3
/min
65
60 to 2000 dm
3
/min
500 dm
3
/min
5.00 dm
3
8 dm
3
/min
80
90 to 3000 dm
3
/min
750 dm
3
/min
5.00 dm
3
12 dm
3
/min
100
145 to 4700 dm
3
/min
1200 dm
3
/min
10.00 dm
3
20 dm
3
/min
125
220 to 7500 dm
3
/min
1850 dm
3
/min
15.00 dm
3
30 dm
3
/min
150
20 to 600 m
3
/h
150 m
3
/h
0.025 m
3
2.5 m
3
/h
200
35 tof 1100 m
3
/h
300 m
3
/h
0.05 m
3
5.0 m
3
/h
250
55 to 1700 m
3
/h
500 m
3
/h
0.05 m
3
7.5 m
3
/h
300
80 to 2400 m
3
/h
750 m
3
/h
0.10 m
3
10 m
3
/h
350
110 to 3300 m
3
/h
1000 m
3
/h
0.10 m
3
15 m
3
/h
400
140 to 4200 m
3
/h
1200 m
3
/h
0.15 m
3
20 m
3
/h
450
180 to 5400 m
3
/h
1500 m
3
/h
0.25 m
3
25 m
3
/h
500
220 to 6600 m
3
/h
2000 m
3
/h
0.25 m
3
30 m
3
/h
600
310 to 9600 m
3
/h
2500 m
3
/h
0.30 m
3
40 m
3
/h