Angle of installation
The sensor must be installed with an angle of inclination of at least 10 ° to the horizontal in an
assembly, support or a suitable process connection. Other angles are not permissible. Do
not
install
the sensor overhead.
!
Note!
Make sure you comply with the instructions for installing sensors. You will find them in the
Operating Instructions for the assembly used.
3.2.3
Mounting location
• Select the installation location so that there is easy access for later calibration.
• Make sure that upright posts and assemblies are secured safely and vibration-free.
• For immersed operation in an activated sludge basin, select an installation location which
produces a typical oxygen concentration.
3.3
Installation instructions
3.3.1
Measuring system
A complete measuring system comprises at least:
• the digital oxygen sensor Oxymax W COS51D
• a transmitter, e.g. Liquiline M CM42
• a special measuring cable, CYK10
• an assembly, e.g. immersion assembly CYA611 or retractable assembly COA451
Optional (see accessories):
• Universal suspension assembly support CYH101 for immersion operation
• Junction box RM (with cable extension)
• Automatic cleaning system Chemoclean with spray head
a0006741-en
Fig. 2:
Permissible angle of installation
10°
10° Not permissible!
Not permissible!
Permissible angle of installation
Содержание Oxymax W COS51D
Страница 1: ...BA413C 07 en 10 08 71083533 Operating Instructions Oxymax W COS51D Digital sensor for dissolved oxygen...
Страница 31: ...Oxymax W COS51D EC Declaration of Conformity Endress Hauser 31 11 EC Declaration of Conformity...
Страница 34: ...Oxymax W COS51D 34 Endress Hauser...
Страница 36: ...www endress com worldwide BA413C 07 en 10 08 Printed in Germany FM SGML 6 0 DT...