11.2 Environment
11.2.1 Ambient temperature
Non-hazardous area versions
0 to 55 °C (32 to 131 °F)
Hazardous area versions
2 to 40 °C (36 to 104 °F)
11.2.2 Storage temperature
-10 to +70 °C (+10 to +160 °F)
11.2.3 Humidity
5 to 95 %
11.2.4 Degree of protection
IP65 and NEMA 4
11.2.5 Electrical safety
Maximum altitude ≤ 2000 m (6560 ft) above MSL
11.3 Process
11.3.1 Process temperature
0 to 90 °C (32 to 194 °F) continuous
Max. 130 °C (266 °F) for 2 hours
11.3.2 Process pressure
Max. 100 bar (1450 psi) absolute, depending on the material, pipe size and process
connection of the flow assembly
11.4 Mechanical construction
11.4.1 Dimensions