• The minimum recommended full scale value is approx. 1/20 of the maximum full scale value
• In most applications, 20 to 50 % of the maximum full scale value can be considered ideal
• A low full scale value must be selected for abrasive media (such as liquids with entrained solids):
flow velocity < 1 m/s (< 3 ft/s).
Pressure loss
To calculate the pressure loss, use the
Applicator
Vibrations
The high oscillation frequency of the measuring tubes ensures that the correct operation of the