Operation options
Liquiphant FTL64
36
Hauser
7
Operation options
7.1
Overview of operation options
7.1.1
Operating concept
• Operation with button and DIP switches on the electronic insert
• Display with optional Bluetooth module and SmartBlue app via Bluetooth® wireless
technology
• Indication of operational status (switch status or alarm status) with optional LED module
(signal lights visible from the outside)
For plastic housing and aluminum housing (standard and Ex d) in conjunction with DC-
PNP (electronic insert FEL62) and relay electronics (electronic inserts FEL64, FEL64DC
7.1.2
Elements on the electronic insert
MIN
>0,7
MAX
>0,5
COM
U = 9...20 V DC
4
3 5
8
7
6
L-
L+
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
A0037705
32
Example of electronic insert FEL64DC
1
COM interface for additional modules (LED module, Bluetooth module)
2
LED, red, for warning or alarm
3
LED, yellow, switch status
4
LED, green, operational status (device is on)
5
Test button, activates functional test
6
DIP switch for setting density 0.7 or 0.5
7
Terminals (3 to 8), relay contact
8
Terminals (1 to 2), power supply
9
DIP switch for configuring MAX/MIN safety mode
7.1.3
Heartbeat diagnostics and verification with Bluetooth®
wireless technology
Access via Bluetooth® wireless technology
1
2
A0033411
33
Remote operation via Bluetooth® wireless technology
1
Smartphone or tablet with SmartBlue app
2
Device with optional Bluetooth module
Содержание Liquiphant FTL64
Страница 64: ...www addresses endress com 71560856 71560856 ...