background image

Operating Instructions 

Liquiline To Go Ex CYM291

Products

Services

Solutions

Содержание Liquiline To Go Ex CYM291

Страница 1: ...Operating Instructions Liquiline To Go Ex CYM291 Products Services Solutions ...

Страница 2: ......

Страница 3: ...f the device has been in contact with process fluids it must be decontaminated disinfected before shipment In that case please attach a corresponding certificate for the health and safety of our service personnel Disposal Please observe the applicable local or national regulations concerning the disposal of waste electrical and electronic equipment Registered Trademarks The following names are reg...

Страница 4: ...ng 17 Configuration pH 17 Configuration Cond 18 Configuration Oxy 19 pH Calibration 20 Conductivity Calibration 24 Oxygen Calibration 27 Measuring 31 Toggling the Measured Value Display 31 Adjusting the Temperature 31 Data Logger 32 Operating Modes of the Data Logger Logger Type 33 Data Logger Menu 35 Configuring the Data Logger 36 Starting the Data Logger using CONT 37 Starting the Data Logger us...

Страница 5: ...44 Endress Hauser Buffer Solutions pH 45 Ready to use quality pH buffer solutions 45 Accessories for pH 45 Conductivity Product Line 46 Conductivity Sensors 46 CLY11 Conductivity Calibration Solutions 47 Accessories for Conductivity 47 Oxygen Product Line 48 Oxygen Sensors 48 Accessories for Oxygen 48 Specifications 49 Index 54 ...

Страница 6: ... The package of the Liquiline To Go Ex CYM291 includes Liquiline To Go Ex CYM291 Meter incl 4 AA batteries and premounted quiver Carrying strap Data carrier with detailed user manuals USB cable 1 5 m Safety instructions Quickstart instructions in various languages Certificates ...

Страница 7: ...allation and first steps Operation Menu structure Calibration Error messages and recommended actions Various languages on CD ROM German English French Italian Spanish Portuguese Brazil Specific Test Report Certificates CAUTION These safety instructions are part of the product documentation and must be observed In official EU languages and others EU Declarations of Conformity ...

Страница 8: ...m drying out Furthermore it can be used for calibration The rugged housing is made of a high performance polymer It provides high impact resistance and dimensional stability even when exposed to extreme moisture Scratch proof clear glass display perfectly readable even after years Very long operating time with one set of batteries 4 x AA for reliable operation even at high or very low operating te...

Страница 9: ...lable and can still be used when the sensor is connected to another Memosens capable device Sensoface Sensoface provides quick information on the sensor condition The three smiley faces as shown on the right represent the sensor condition during measurement and after a calibration When the condition deteriorates an INFO message gives a hint to the cause Programmed buffers Programmed buffers is a v...

Страница 10: ...on Hook A fold out hook on the back allows suspending the meter This leaves your hands free for the actual measurement The rating plate is located beneath the hook Protective Cover and Hook Combined Cover and hook can be joined together to form a benchtop stand allowing com fortable and fatigue free working at a lab bench or desk Overview ...

Страница 11: ... of icons Sensoface battery icon etc Some typical displays are shown here pH measurement display of measured value tempera ture date and time Oxygen calibration step 1 calibration in air Logger data for conductivity display of measured value memory location temperature date and time Clock display of hours and minutes seconds and date Oxygen calibration step 2 adjusting the relative humidity Overvi...

Страница 12: ...art up Switches the meter on Activates measuring mode Stops the data logger Starts calibration Activates configuration Confirms entries Displays time and date allows setting the clock using set View stored values Holds and saves a measured value allows setting and starting the logger by press ing page 32 When this icon is displayed you can use the arrow keys for navigation Overview ...

Страница 13: ... Do not operate the device when one of the following conditions applies the device shows visible damage the device fails to perform the intended function prolonged storage at temperatures above 70 C severe transport stresses In this case a professional routine test must be performed This test should be carried out at our factory Precautions for application in hazardous locations WARNING Only open ...

Страница 14: ...ries 4x each Temp class Ambient temperature range Duracell MN1500 T4 10 C Ta 40 C Energizer E91 T3 10 C Ta 50 C Power One 4106 T3 10 C Ta 50 C Panasonic Pro Power LR6 T3 10 C Ta 50 C A battery icon in the display indicates the battery power level Icon fully filled Batteries at full capacity Icon partially filled Battery capacity is sufficient Icon empty Battery capacity not sufficient calibration ...

Страница 15: ...ture probe you must switch off the meter and then switch it on again Start Up Memosens sensors have a cable coupling which allows convenient replacement of sensors while the cable remains connected to the meter The connecting cable is connected to socket b M8 4 pins or e M12 8 pins a b c d Connections a Micro USB port b M8 4 pins for Memosens lab cable c Temperature probe GND d Temperature probe e...

Страница 16: ...ode When the meter is switched on with the key it immediately switches to measuring mode Depending on the connected sensor and the specific measur ing task several steps for configuration and calibration must be performed as described on the following pages Error message Battery charging level Sensor condition Memosens sensor Temperature detection sensor separate or manual Icons Important informat...

Страница 17: ...OG BUF FERS FREE CAL 01 Endress Hauser 2 00 4 01 6 98 9 95 11 87 02 Mettler Toledo 2 00 4 01 7 00 9 21 03 Knick CaliMat 2 00 4 00 7 00 9 00 12 00 04 Ciba 94 2 06 4 00 7 00 10 00 05 NIST technical 1 68 4 00 7 00 10 01 12 46 06 NIST standard 1 679 4 006 6 865 9 180 07 HACH 4 01 7 00 10 01 12 00 08 WTW techn buffers 2 00 4 01 7 00 10 00 09 Hamilton 2 00 4 01 7 00 10 01 12 00 10 Reagecon 2 00 4 00 7 0...

Страница 18: ...it mS cm S m TDS Factor 0 0 1 0 if display TDS TC OFF LINEAR NLF NACL HCL NH3 NAOH if display Cond TC LINEAR 0 0 20 0 K 2 1 K if TC LINEAR REF Temp 0 100 C 25 C 32 212 F 77 F if TC LINEAR CAL CELL CONST COND 25 C 74 0µS cm 25 C 149 6µS cm 25 C 1 406mS cm 25 C 12 64mS cm 25 C 107 00mS cm FREE CAL Auto OFF OFF 0 1h 1h 6h 12h Temp Unit C F Time Format 24h 12h Date Format dd mm yy mm dd yy Default NO ...

Страница 19: ...sing arrow keys confirm by pressing Display 1 Saturation in air Concentration in mg l Display 2 OFF date time date time Altitude 0 4000 m Salt Correct 0 0 45 0 g kg CAL AIR CAL ZERO CAL DATA INPUT FREE CAL CAL Timer OFF 1 99 days Auto OFF OFF 0 1h 1h 6h 12h Temp Unit C F Time Format 24h 12h Date Format dd mm yy mm dd yy Default NO YES reset to factory settings Note All data logger entries will be ...

Страница 20: ... display of CAL DATA 1 2 3 CAL POINTS ZERO POINT SLOPE Then the meter switches to measuring mode Programmed Buffers Calibration Calibration with automatic buffer recognition The calibration method is selected in the configuration menu Calibration is required to adjust the sensor to the meter It is indis pensable for achieving comparable and reproducible measurement results pH Calibration Please no...

Страница 21: ...slope The calibration data will be displayed successively Date and time ZERO POINT SLOPE Then the meter switches to measuring mode DATA INPUT Calibration Calibration by entering known sensor values The calibration method is selected in the configuration menu pH Calibration Please note To abort calibration you can press at any time ...

Страница 22: ... is repeated mV value blinks until calibration is completed then successive display of CAL DATA 1 2 3 CAL POINTS ZERO POINT SLOPE Then the meter switches to measuring mode MANUAL Calibration Manual calibration The calibration method is selected in the configuration menu Please note To abort calibration you can press at any time This will be confirmed by the display message CAL ABORTED Exception Wh...

Страница 23: ...ed calibration method PROG BUFFERS DATA INPUT or MANUAL Perform the selected calibration see PROG BUFFERS DATA INPUT or MANUAL calibration FREE CAL Calibration Free selection of calibration method FREE CAL calibration is selected in the configuration menu pH Calibration ...

Страница 24: ...ation Calibration by entry of cell constant The calibration method is selected in the configuration menu Measurement CAL COND Dip sensor in solution Value blinks Use st to adjust the temperature corrected conductivity value NOTICE Here the meter does not perform a temperature compensation Calibration will be performed Automatic return to measuring mode COND Calibration Calibration by entry of cond...

Страница 25: ...perature Cal solution conductivity Hourglass blinks Calibration will be performed Automatic return to measuring mode Conductivity Calibration NOTICE Make sure that the values of the calibration solutions used correspond exactly to those specified in this manual If not the resulting cell constant will be incorrect When calibrating in a liquid make sure that the sensor the separate temperature probe...

Страница 26: ... the configuration menu Measurement CAL CELL CONST blinks Use st to select the desired calibration method CELL CONST COND 25 C 74 0µS cm 25 C 149 6µS cm 25 C 1 406mS cm 25 C 12 64mS cm 25 C 107 00mS cm Perform the selected calibration see CELL CONST COND or calibration solution Conductivity Calibration ...

Страница 27: ...adjust the correct value for relative humidity xxx nA blinks Hourglass blinks Calibration will be performed CAL DATA Date SLOPE xxx nA Slope calibration data is displayed Automatic return to measuring mode AIR CAL Calibration Calibrating the slope in air The calibration method is selected in the configuration menu Please note To abort calibration you can press at any time ...

Страница 28: ...bilized CAL DATA Calibration will be performed Date ZERO P xxx nA Zero calibration data is displayed Date SLOPE xxx nA Slope calibration data is displayed Automatic return to measuring mode ZERO CAL Calibration Zero calibration with oxygen free medium The calibration method is selected in the configuration menu Please note To abort calibration you can press at any time ...

Страница 29: ...menu Measurement CAL DATA INPUT xx blinks nA ZERO POINT Use st to adjust the known value for the sensor zero point xxx blinks nA SLOPE Use st to adjust the known value for the sensor slope Calibration will be performed Automatic return to measuring mode Please note To abort calibration you can press at any time Oxygen Calibration ...

Страница 30: ... FREE CAL calibration is selected in the configuration menu Measurement CAL AIR CAL blinks Use st to select the desired calibration method AIR CAL ZERO CAL DATA INPUT Perform the selected calibration see AIR CAL ZERO CAL or DATA INPUT calibration Oxygen Calibration ...

Страница 31: ...e key you can hold and save a measured value see data logger page 32 Toggling the Measured Value Display During measurement you can toggle the measured value display by pressing pH between pH and mV Cond between compensated and uncompensated measured value when temperature compensation SAL or TDS are activated Oxy not applicable Adjusting the Temperature When you connect a sensor without temperatu...

Страница 32: ...d signal controlled logging SHOT manual logging by pressing the key The data logger records up to 5000 entries and saves them in a circular buffer Already existing entries will be overwritten The following data are recorded primary value temperature time stamp and device status Data Logger Measured values are displayed Logger type Date Data logger activated Primary process variable Temperature Dis...

Страница 33: ...last recorded value 1 Manual logging when logger is deactivated Measurement Logger deactivated Measured value is maintained Proposed address blinks address of the last recorded value 1 If desired Select start address using st Measured value is saved to the desired address e g for overwriting an incorrect measurement Example Logger type INT Data Logger Interval INT In this mode the measured values ...

Страница 34: ...Difference Interval combined DIFF INT When the delta range related to the last DIFF entry is exceeded a new entry is creat ed example entry A and the delta range is displaced upwards or downwards by the delta value As long as the measured value remains within the delta range logging is performed at the preset interval The first DIFF entry is automatically created when the data logger is started Ti...

Страница 35: ... 0 1 50 0 C 1 0 C OFF 0 1 100 F 1 0 F INT Interval h mm ss 0 00 01 9 59 59 12 02 00 AM DIFF INT DIFF See logger type DIFF INT See logger type INT SHOT Currently selected process variable is recorded Data Logger Menu Logger display Select using arrow keys confirm by pressing CONT Select start address and start the data logger START Deletes all entries and starts the data logger at start address 000...

Страница 36: ...r START blinks t Logger DEL blinks t Logger SET blinks Logger Current logger type blinks Select desired logger type using st DIFF INT DIFF INT or SHOT Select the appropriate parameters using st and confirm each selection by press ing When configuration is finished CONT blinks You can start the data logger by selecting START or CONT see page 37 Data Logger ...

Страница 37: ...aved to the selected start address exception SHOT FREE MEMORY is displayed LOGGER and active logger type icons are displayed Starting the Data Logger using START Prerequisite Data logger is configured All existing entries are deleted The start address for saving the values is 0001 Every time the meter has been switched off the data logger must be restarted exception SHOT Measurement Measured value...

Страница 38: ...ed values Measurement The RCL icon and the last record ed value is displayed Use st to select the desired address Empty memory locations will also be displayed or Return to measurement Example Measured value stored at location 0026 Example Empty memory location 0004 Data Logger ...

Страница 39: ... blinks PRESS SET All stored data are deleted 0000 DELETED is displayed Stopping the Data Logger You can stop the data logger at any time by pressing the key Measurement logger activated Data logger is stopped LOGGER and active logger type icons are no longer displayed It is still possible to hold a measured value by pressing and send it to any desired address Data Logger ...

Страница 40: ...as follows Display of time date Hour display blinks SET HOUR Set value Minute display blinks SET MINUTE Set value Seconds display blinks and shows 00 Clock is started the seconds count up Year display blinks SET YEAR Set value Month display blinks SET MONTH Set value Day display blinks SET DAY Set value Display of corrected time date 40 pH Oxy Cond ...

Страница 41: ...equest Measurement can still be performed After a calibration the corre sponding Sensoface icon friendly neutral sad is shown together with the calibration data Otherwise Sensoface is only visible in measuring mode The most important error messages and Sensoface info messages are shown on the inside of the protective cover A complete list of messages and their meanings is provided in the following...

Страница 42: ... sensor soon Calibrate or replace the sensor The neutral and sad Sensoface icons are accompanied by an INFO message to give a hint to the cause of deterioration Sensoface Message Cause INFO 1 Calibration timer INFO 3 Sensocheck INFO 5 Zero Slope INFO 6 Response time INFO 7 Operating point asymmetry potential INFO 8 Leakage current INFO 9 ORP offset INFO 10 Polarization ...

Страница 43: ...l buffers Use a buffer solution with a different nominal value before starting the next calibration step ERROR 9 Calibration error Buffer unknown Make sure that you use the same buffer set as configured ERROR 10 Calibration media interchanged Repeat calibration ERROR 11 Measured value unstable Stability criterion not met Leave the sensor in the liquid until the temperature is stable If this does n...

Страница 44: ...tal pH sensor Ceraliquid CPS42D Digital ORP sensor Ceragel CPS71D Digital pH sensor Ceragel CPS72D Digital ORP sensor Memosens CPS76D Combined digital pH ORP sensor Orbipore CPS91D Digital pH sensor Orbipore CPS92D Digital ORP sensor Memosens CPS96D Combined digital pH ORP sensor Ceramax CPS341D Digital non glass pH sensor Tophit CPS441D Digital non glass pH sensor Tophit CPS471D Digital non glass...

Страница 45: ...ce material of the National Institute of Standards and Technol ogy NIST in accordance with DIN 19266 are used as secondary reference buffer solutions CPY20 Buffer Sets Quantity pH 2 00 5000 ml 100 ml 250 ml pH 4 01 5000 ml 100 ml 250 ml 18 ml pH 6 98 5000 ml 100 ml 250 ml 18 ml pH 9 95 5000 ml 100 ml 250 ml pH 11 87 5000 ml 100 ml 250 ml Accessories for pH Item 1 5 m sensor cable ATEX CYK20 BAB1C2...

Страница 46: ...ator Sensor Type Condumax CLS15D Conductivity sensor Condumax CLS16D Conductivity sensor Condumax CLS21D Conductivity sensor Memosens CLS82D Conductivity sensor Memosens sensors have a cable coupling which allows convenient replacement of sensors while the cable remains connected to the meter ...

Страница 47: ...mparative measurement in ultrapure water up to max 20 μS cm Product Configurator on the product page www endress com cly421 The Product Configurator can be accessed at www endress com CLY11 Conductivity Calibration Solutions CLY11 A 74 μS cm reference temp 25 C 77 F 500ml 16 9 fl oz CLY11 B 149 6 μS cm reference temp 25 C 77 F 500ml 16 9 fl oz CLY11 C 1 406 mS cm reference temp 25 C 77 F 500ml 16 ...

Страница 48: ...e Link to Product Configurator Oxymax COS22D digital oxygen sensor Oxygen Product Line Accessories for Oxygen Item COS22Z maintenance kit 1 5 m sensor cable ATEX CYK20 BAB1C2 The Product Configurator can be accessed at www endress com ...

Страница 49: ...osion protection CYM291 Global IECEx Ex ia IIC T4 T3 Ga Europe ATEX II 1 G Ex ia IIC T4 T3 Ga Connections 1x M8 socket 4 pins for Memosens lab cable 1 x M12 socket 8 pins for Memosens sensors 2 x 4 mm socket for separate temperature detector 1 x micro USB B for operation without batteries Be sure to observe the safety instructions when using the USB port Display LCD STN 7 segment display with 3 li...

Страница 50: ...ating conditions Ambient temperature 10 C Ta 40 C 14 104 F T4 Duracell MN1500 10 C Ta 50 C 14 122 F T3 Energizer E91 Power One 4106 and Panasonic Pro Power LR6 Transport Storage temp 25 70 C 13 158 F Relative humidity 0 95 short term condensing allowed Housing Material PA12 GF30 silver gray RAL 7001 TPE black Protection IP 66 67 with pressure compensation Dimensions Approx 132 x 156 x 30 mm Weight...

Страница 51: ... zero and slope 01 Endress Hauser 2 00 4 01 6 98 9 95 11 87 Programmed buffers buffer sets 02 Mettler Toledo 2 00 4 01 7 00 9 21 03 Knick CaliMat 2 00 4 00 7 00 9 00 12 00 04 Ciba 94 2 06 4 00 7 00 10 00 05 NIST technical 1 68 4 00 7 00 10 01 12 46 06 NIST standard 1 679 4 006 6 865 9 180 07 HACH 4 01 7 00 10 01 12 00 08 WTW techn buffers 2 00 4 01 7 00 10 00 09 Hamilton 2 00 4 01 7 00 10 01 12 00...

Страница 52: ... water with traces Display resolution autoranging Conductivity 0 001 μS cm c 0 05 cm 1 0 01 μS cm c 0 05 0 2 cm 1 0 1 μS cm c 0 2 cm 1 Resistivity 00 00 99 99 MΩ cm Salinity 0 0 45 0 g kg 0 30 C TDS 0 1999 mg l 10 40 C Sensor standardization Cell constant Input of cell constant with simultaneous dis play of conductivity value and temperature Input of solution Input of conductivity of the calibrati...

Страница 53: ...12 socket 8 pins for Memosens sensors Display ranges 1 Saturation 0 000 200 0 Concentration 000 μg l 20 00 mg l Temperature meas range 1 20 150 C Sensor standardization Automatic calibration in air 100 RH Zero calibration 1 Ranges depending on Memosens sensor Specifications ...

Страница 54: ...rdous locations 14 Battery capacity 14 Battery charge indicator 14 Battery compartment 13 Battery icon 14 Battery replacement 13 Benchtop stand 10 Buffer sets CPY20 45 Buffer set selection 17 Buffer solutions 45 C Calibration conductivity 24 Calibration set Conducal CLY421 47 CD ROM 7 Cell constant Cond calibration 24 Certificates 7 Charge level of batteries 14 Clearing the datalogger 39 Clock 40 ...

Страница 55: ...ger 37 Cyclic recording of measured values 33 D DATA INPUT Oxy calibration 29 DATA INPUT pH calibration 21 Data logger 32 Data logger configuration 36 Data logger icons 32 Data logger menu 35 Data memory 32 Data of the meter 49 Date 40 Default configuration 17 Deleting data logger entries 39 Delta range data logger 34 Device configuration Cond 18 Device configuration Oxy 19 Device configuration pH...

Страница 56: ...rations of Conformity 7 F FREE CAL free selection of calibration method Cond 26 FREE CAL free selection of calibration method Oxy 30 FREE CAL free selection of calibration method pH 23 H Hazardous location batteries 14 Hazardous location sensors 15 Holding the measured value 33 Hook 10 Hours display 40 I Icons 16 Icons for data logger 32 INFO messages 42 Inserting the batteries 13 Interrupting the...

Страница 57: ...5 Menu structure of Cond configuration 18 Menu structure of data logger 35 Menu structure of Oxy configuration 19 Menu structure of pH configuration 17 Messages 41 Messages Sensoface 42 Micro USB port 15 Minutes display 40 N Nitrogen 5 0 28 O on off key 12 Operating modes of the data logger 33 ORP sensors 44 Overview of Cond configuration 18 Overview of error messages 43 Overview of Oxy configurat...

Страница 58: ...45 pH calibration DATA INPUT 21 pH calibration FREE CAL 23 pH calibration MANUAL 22 pH configuration 17 pH sensors 44 Ports 15 Power on 16 Power One 4106 battery 14 Product range 44 Programmed buffers description 9 Programmed buffers pH calibration 20 Protective cover 10 Q Quickstart guides 7 R Rating plate 10 Real time clock 40 Recorded data display 38 Redox sensors 44 Registered trademarks 3 Rep...

Страница 59: ... measurement 17 Setting the data logger 36 Setup Cond configuration 18 Setup Oxy configuration 19 Setup pH configuration 17 SHOT data logger mode 33 Smiley 42 Specifications 49 Specific test report 7 Start address data logger 33 Starting the data logger using CONT 37 Starting the data logger using START 37 START starting the data logger 37 Start up 13 Status messages 41 Stopping the data logger 39...

Страница 60: ...iguration 19 Table of pH configuration 17 Technical data 49 Temperature class 14 Temperature manual adjustment 31 Temperature probe 15 Toggling the measured value display 31 Trademarks 3 Triangle icons 12 V Value added features 9 Viewing recorded data 38 Viewing the logger data 38 W Warranty 3 Z ZERO CAL Oxy calibration 28 Index ...

Страница 61: ......

Страница 62: ......

Страница 63: ......

Страница 64: ...TA 209 4MU EHEN03 Software version 01 04 xx 71524833 098615 www addresses endress com Endress Hauser Conducta GmbH Co KG Dieselstraße 24 70839 Gerlingen Germany Phone 49 7156 209 790 Fax 49 7156 28 158 ...

Отзывы: