Commissioning
Source container FQG66
28
Hauser
4 →
5
3
1
2
A0027133
A0027134
‣
Fit the cover (3).
‣
Secure the cover with the
screws (2) (6mm across flats)
and fit the padlock (1) back on.
L
CAUTION
Risk of injury if the device is operated without a cover
‣
Only operate the device with the cover mounted.
7.3.3
Manual version with/without proximity switch
(US version order code 010 "Approval", option AE "NRC")
NOTICE
According to NRC requirements, it must be possible to switch off the source container
at any time without the need for any special tools (e.g. key for padlock).
‣
Follow the instructions below!
1 →
2 →
3 →
1
2
3
1
A0023595
A0027121
A0027375
‣
Remove padlock (1). Turn the
screws (2) (6mm across flats)
on the cover three to four
times to release them.
‣
Remove the cover (3).
‣
Fit the padlock (1) on the
source retainer.