3.10
Measuring tape and measuring wire installation
1)Extend measuring wire while folding back a length of 1.5 m wire not to twist.
2)Before you start this process, open the covers of Sheave elbow and gauge head.
Note!
• Be careful not to bend or scratch the measuring tape.
• Be sure to watch out for the twisting of the measuring tape inside the tank or the pipe.
• During operation, check to make sure that the measuring tape and measuring wire do not go off the roller of
the Sheave elbow. Inspection is necessary after the installation.
• Connection part between the float and the measuring tape is impossible to repair after the tank is filled with
the fluid. So, please make sure to do a thorough inspection after the connection is finished.
Extend measuring wire
while folding back a length of 1.5m
Approx.1.5
with smoll hole
without smoll hole
Cover
Sheave elbow
3 Installation