Cubemass DCI
16
Hauser
Pressure loss coefficients for Cubemass DCI
A0011692
Pressure loss diagram for water
Pressure loss (US units)
Pressure loss depends on the nominal diameter and the fluid properties.
The "Applicator" PC software is available from Hauser and can be used to calculate the pressure loss
in US units. The "Applicator" program contains all the important device data which allows the measuring
system arrangement to be optimized.
The software is used for the following calculations:
• Nominal diameter of the sensor with fluid properties such as viscosity, density etc.
• Pressure loss downstream from the measuring point
• Conversion of mass flow to volume flow etc.
• Simultaneous display of variables determined by different measuring devices
• Determining measuring ranges
The Applicator program runs on any IBM-compatible PC with Windows.
DN
d
K
K1
[mm]
[inch]
[m]
1
1/24"
1.40
⋅
10
–3
7.78
⋅
10
10
9.50
⋅
10
10
2
1/12"
2.50
⋅
10
–3
5.04
⋅
10
9
9.51
⋅
10
9
4
1/8"
3.90
⋅
10
–3
6.31
⋅
10
8
1.66
⋅
10
9
6
¼"
5.35
⋅
10
–3
1.49
⋅
10
8
4.97
⋅
10
8
[mbar]
[kg/h]
10000
1000
100
10
1
0.1
1
10
100
1000
DN 1
DN 2
DN 4
DN 4
DN 4
DN 6