Cubemass DCI
8
Hauser
Electrical connection,
terminal assignment
Electrical values for inputs/outputs
È
Operating Instructions
Electrical connection,
Remote version
A0003681
Connecting the remote version
a
Transmitter wall-mount housing: non-hazardous area
→
separate documentation
b
Transmitter wall-mount housing: ATEX II2G / Zone 1 / NEC/CEC
→
separate Ex documentation
c
Sensor connection housing
d
Cover of connection compartment or connection housing
e
Connecting cable
Terminal No.: 4/5 = gray; 6/7 = green; 8 = yellow; 9/10 = pink; 11/12 = white; 41/42 = brown
Supply voltage
85 to 260 V AC, 45 to 65 Hz
20 to 55 V AC, 45 to 65 Hz
16 to 62 V DC
Cable entries
Power supply and signal cables (inputs/outputs):
• Cable entry M20 × 1.5 (8 to 12 mm / 0.31 to 0.47")
• Threads for cable entries, ½" NPT, G ½"
Connecting cable for remote version:
• Cable entry M20 × 1.5 (8 to 12 mm / 0.31 to 0.47")
• Threads for cable entries, ½" NPT, G ½"
Terminal No. (inputs/outputs)
Order version
20 (+) / 21 (-)
22 (+) / 23 (-)
24 (+) / 25 (-)
26 (+) / 27 (–)
Fixed communication boards (permanent assignment)
8CN**–**S*********
–
–
Frequency output,
Ex i, passive
Current output, Ex i,
active, HART
8CN**–**T*********
–
–
Frequency output,
Ex i, passive
Current output, Ex i,
passive, HART
8CN**–**Q*********
–
–
Status input
MODBUS RS485
Flexible communication boards
8CN**–**D*********
Status input
Relay output
Frequency output
Current output, HART
8CN**–**M*********
Status input
Frequency output 2
Frequency output 1 Current output, HART
8CN**–**N*********
Current output
Frequency output
Status input
MODBUS RS485
8CN**–**1*********
Relay output
Frequency output 2
Frequency output 1 Current output, HART
8CN**–**2*********
Relay output
Current output 2
Frequency output
Current output 1, HART
8CN**–**7*********
Relay output 2
Relay output 1
Status input
MODBUS RS485
4
5
6
7
8
9
10
11 12
41 42
4
5
6
7
8
9
10
11 12
41 42
S1 S1 S2 S2 GND TM TM TT TT
+
+
+
+
+
+
+
+
S1 S1 S2 S2 GND TM TM TT TT
a
b
c
d
d
d
e