Electrical connection
Cerabar PMC51B HART
16
Hauser
6.2.9
Available device plugs
In the case of devices with a plug, it is not necessary to open the housing for connection
purposes.
Use the enclosed seals to prevent the penetration of moisture into the device.
Devices with valve plug
+
2
1
–
+
A
B
BU BN GNYE
2
1
3
+
–
–
A0023097
3
BN = brown, BU = blue, GNYE = green/yellow
A
Electrical connection for devices with valve connector
B
View of the plug-in connection on the device
Devices with a Harting plug Han7D
Han7D
–
+
+
–
–
+
A
B
1
5
4
6
7
8
2
3
A0041011
A
Electrical connection for devices with Harting plug Han7D
B
View of the plug-in connection on the device
-
Brown
Green/yellow
+
Blue