background image

Page 16

32188-0-0616

PLEASE NOTE:  

When ordering parts, it is very important that  

part number

 and 

description

 of part coincide.

  USE ONLY MANUFACTURER'S REPLACEMENT PARTS.  USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

PARTS LIST

Index 

No.

Part No. Description

1

11762

Outer Casing Top

2

R618

Motor Mount (Four Required)

3

11764

Motor Mounting Bar (Two Required)

4

M147

Gasket (Two Required)

5

R619

Motor

6

11787

Fan Blade

7

11766

Fan Housing 

8

DV559

Upper Front Panel 

9

11759

Side Panel 

10

DV613

Right Inner Shield

11

DV725

Vent Cap 

12

DV131

Outside Mounting Plate

13

DV548

air Inlet Tube

14

DV524

Flue Outlet Tube

15

DV600

Vent Kit Complete 

(Nos. 11, 12, 13, 14)

16

DV1386

air Drop 

17

M96

Gasket for Flue Outlet Flange

18

DV579C

Combustion Chamber 

19

R1536

Bushing

20

11765

Switch Compartment assembly

21

R630

Limit Control

22

R1941

Fan Control

23

DV832

Switch Compartment Cover

24

DV562

Lower Front Panel 

25

DV826

Rear Burner 

26

R685

Thermocouple

27

R622L

Pilot with Orifice LP Gas

27

R622N

Pilot with Orifice Natural Gas

28

DV808

Pilot Tubing

29

DV824

Front Burner 

30

P8842

Main Burner Orifice Natural Gas (Two 

Required)

30

P8853

Main Burner Orifice LP Gas (Two 

Required)

31

DV687

Manifold and Plate assembly

32

M148

Manifold Gasket

33

M155

Gasket for Observation Hole Cover

34

DV781

Lighting Hole Cover w/Mica

35

DV064

Cover Plate for Observation Hole

36

DV775

Seal Bracket

37

M147

Gasket Tubing Seal

38

DV847

Burner Door Natural Gas

38

DV972

Burner Door LP Gas

39

DV779

Gasket for Burner Door

40

P112

Manifold Union

41

R5655

Gas Valve VR8200C LP Gas

41

R2148

Gas Valve VR8200C Natural Gas

42

UH810

Transformer Mounting Bracket

43

R1995

Transformer

44

UH451

Junction Box Cover

45

DV967

Outer Casing Bottom 

46

R1515

Bushing

47

R2708

Piezo Ignitor

48

DV571

Control Compartment Divider

49

DV671

Manifold Support

50

DV765

Gasket  for Chamber Air Inlet (Top & 

Bottom) (Two Required)

51

DV764

Gasket for Chamber Air Inlet (Sides) 

(Two Required)

52

R690

Cord Set

53

R1404

Bushing

54

DV614

Left Inner Shield

55

11759

Side Panel

Not 

Shown

R9832

Wiring assembly Upper

Not 

Shown

R9833

Wiring assembly Lower

Not 

Shown

R734

Lighter Rod

Not 

Shown

742265

Pilot Orifice LP Gas

Not 

Shown

R3469

Pilot Orifice Natural Gas

Index 

No.

Part No. Description

Содержание DVC55SPPXLP-1

Страница 1: ...combustion which can cause death or serious illness Installer Leave this manual with the appliance Consumer Retain this manual for future reference WARNING If the information in these instructions ar...

Страница 2: ...duction 6 Specifications 6 Gas Supply 7 8 Clearances 8 Installation Instructions 9 11 Lighting Instructions 12 Pilot Flame Characteristics 13 Main Burner Flame Characteristics 13 Wiring 14 Service and...

Страница 3: ...The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpet ing bedding materials etc It i...

Страница 4: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clo...

Страница 5: ...oxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be pe...

Страница 6: ...ied Installing Agency Installation and replacement of gas piping gas utilization equip ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency The term...

Страница 7: ...local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases The gas lines must be checked f...

Страница 8: ...distance from the center of the vent cap to the nearest outside corner or obstruction is 24 inches CLEARANCES Checking Manifold Pressure Both Propane and Natural gas valves have a built in pressure re...

Страница 9: ...provided Side outlet kit 10 boot assembly with register SOK 1 for warm air discharge into an adjoining room may be installed on either side of the furnace at the required clearance of 4 inches to adj...

Страница 10: ...ove old furnace cement from both ends of 4 diameter flue outlet tube 3 Attach 6 diameter air inlet tube onto the collar of air drop assembly Attach caulked outside mounting plate into the 6 diameter a...

Страница 11: ...e projection 2 x 4 framing whose outside dimensions match the overall dimensions of the mounting plate is recommended The 2 x 4 framing protects siding from possible warpage or discoloration All joint...

Страница 12: ...power to the appliance FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of l...

Страница 13: ...emovingthe burner door from the combustion chamber remove rear burner pilot burner and front burner With front and rear burners removed from furnace force water into the ribbon ports and dry with air...

Страница 14: ...toggle switch or thermostat remove the wire nut from the two wires from the valve Run additional wire from the valve wires to the ON OFF device Install the ON OFF device in the same room as the furnac...

Страница 15: ...r Does Not Light Pilot With air in the gas line such as when the furnace is first installed or was off all summer the pilot flame may be too lean to ignite on the first few trials Turn the control val...

Страница 16: ...l Gas 28 DV808 Pilot Tubing 29 DV824 Front Burner 30 P8842 Main Burner Orifice Natural Gas Two Required 30 P8853 Main Burner Orifice LP Gas Two Required 31 DV687 Manifold and Plate Assembly 32 M148 Ma...

Страница 17: ...Page 17 32188 0 0616 PARTS VIEW...

Страница 18: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numb...

Страница 19: ...le cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from t...

Страница 20: ...mfort Systems Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please cont...

Страница 21: ...rieuses maladies Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflammables dans le voisnage de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE...

Страница 22: ...st chaud lorsque le radiateur est en fonction L installation et la r paration doivent tre faites par une per sonne qualifi e L appareil doit tre inspect avant l usage et au moins une fois par ann e pa...

Страница 23: ...bas Attendez que les pompiers vous assurent de la s ret de ces endroits avant d y aller Utiliser le t l phone de votre voisin et appeler les pompiers et une personne entra n e avec le propane Ne pas...

Страница 24: ...e gaz d entrer par le capuchon de l vent Emplacement de l Ouverture dans le Mur Le radiateur doit tre situ sur un mur ext rieur Trouver les montants du mur ainsi l ouverture dans le mur sera entre les...

Страница 25: ...d espace libre aux mat riaux combus tibles venant du d gage ment du registre de chaque c t Entr e de gaz Enlever plinthe et moulure ouverture d vent 7 1 2 19cm Mur ar ri re Minimum d espace libre au c...

Страница 26: ...l entr e de la pluie Attacher la plaque ext rieure de montage au mur ext rieur avec 4 vis 10 x 1 38mm Les vis sont fournies 4 Appliquer du ciment pour radiateur au collet de la sortie Emplacement de l...

Страница 27: ...ourrev tementnedoitpasexc derune paisseur totale de 13 33 02cm pour le DV 55 voir Figure 5a AVERTISSEMENT Lorsque l ensemble d vent pour le rev tementenvinyleDV 822oulaconstructionfaitede2 x 4 5 08cm...

Страница 28: ...x et de raccords en m tal ondul ANS Z21 45 Connexions flexibles d appareil autre qu en m tal Les connexions ci dessus peuvent tre utilis es si elles sont accept es par les autorit s ayant juridiction...

Страница 29: ...index no 4 pi ce no 712059 Les joints d tanch it doivent tre tir s pour s adapter sur les boulons du moteur dans les espaces pour joint d tanch it Le moteur et les joints d tanch it peuvent tre insta...

Страница 30: ...tournerle bouton de contr le de gaz N utiliserjamais des outils Si vousnepouvezpaspousseroutournerleboutonavecvos mains n essayerpasdeler parer appeleruntechnicien qualifi Forcer ou essayer de r parer...

Страница 31: ...a veilleuse et r allumer La veilleuse s enflamme mais s teint lorsque le bouton est rel ch 1 Suivre les instructions et appuyer sur le bouton plus long temps et fermement 2 D terminer si la flamme de...

Страница 32: ...semblage du br leur avant 30 P8842 Br leur principal avec ouverture gaz naturel exige deux 30 P8853 Br leur principal avec ouverture gaz propane exige deux 31 DV687 Tuyau de gaz et assemblage de plaqu...

Страница 33: ...Page 13 32188 0 0616 Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 2623...

Страница 34: ...aiement pour attester de la date d achat et tablir la p riode de garantie Acc s imm diat l appareil pour la r paration Ce qui n est pas couvert Dommages pouvant r sulter de l emploi de l emploi abusif...

Страница 35: ...Page 15 32188 0 0616 NOTES DE SERVICE...

Страница 36: ...ire Comfort Systems Inc Belleville IL Pour toute question g n rale concernant nos produits veuillez nous envoyer un courriel info empirecomfort com Pour toute question d entretien ou de r paration veu...

Отзывы: