Page 14
32188-0-0616
Figure 13
Wiring
The appliance, when installed, must be electrically grounded
in accordance with local codes or, in the absence of local
codes, with the
National Electrical Code, ANSI/NFPA 70 or
Canadian Electrical Code, CSA C22.1,
if an external electrical
source is utilized.
This appliance is equipped with a three-
prong [grounding] plug for your protection against shock
hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove
the grounding prong from this plug.
For an ungrounded
receptacle, an adapter, which has two prongs and a wire for
grounding, can be purchased, plugged into the ungrounded
receptacle and its wire connected to the receptacle mounting
screw. With this wire completing the ground, the appliance
cord plug can be plugged into the adapter and be electrically
grounded. a
7/8
" hole is provided in the junction box for use
with a conduit connector if local codes require this type of
protection.
CAUTION:
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after
servicing.
To Conserve Gas: Turn off pilot when heater is not in use.
Installing the ON/OFF Device
To install an ON/OFF device (such as a wall switch, remote,
toggle switch, or thermostat), remove the wire nut from the
two wires from the valve. Run additional wire from the valve
wires to the ON/OFF device. Install the ON/OFF device in the
same room as the furnace following the installation instruc-
tions supplied with it. In the absence of instructions, install the
ON/OFF device 4 to 5 feet above the floor on an interior wall
not affected by another heating source (i.e. stove or water
heater) or the temperature of an adjoining room.
WIRING
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED
WITH THIS UNIT MUST BE REPLACED, IT MUST
BE REPLACED WITH 150°C THERMOPLASTIC
4/64 THICK OR ITS EQUIVALENT.
120V. 60Hz. LESS THAN 3 AMPS
S´IL Y A UN FIL ORIGINAL FOURNI AVEC
L´APPAREIL QUI DIOT ÊTRE REMPLACÉ. IL DOIT
ÊTRE REMPLACÉ AVEC UN FIL
THERMOPLASTIQUE 150°C.
120V. 60Hz. MOINS DE 3 AMPS.
——————
————————————————————
———————————————————————————
VALVE DE GAZ
PÉRIPHÉRIQUES
120 VOLTS
LADDER WIRING DIAGRAM
——————————————————————————
DIAGRAMME À L´ÉCHELLE
D´INSTALLATION ÉLECTRIQUE
YELLOW
———
—
————————
JAUNE
WHITE
———
—
————————
BLANC
BLACK
———
—
————————
NOIR
RED
—
ROUGE
RED
—
ROUGE
TRANSFORMER
———
—— ————
——————————————
—
TRANSFORMATEUR
24 VOLTS
MOTOR
————— ————
—
MOTEUR
AUTO FAN
———
—— ————
———————
—
VENTILATEUR
AUTO
GAS VALVE
———
—— ————
—————————
—
LIMIT CONTROL
———
— ————
——————————— —
CONTROL DE
TOLERANCE
ON/OFF DEVICE
———
— ————
——————————— —
ON/OFF
WIRE NUT
—
— ————
———————---------------- —
FILS TORSADÉS
LOW VOLTAGE (BAS VOLTAGE)
120 VOLTS
SCHEMATIC WIRING DIAGRAM
——————————————————————————————
SCHÉMA
É
INSTALLATION LECTRIQUE
JUNCTION BOX
——
—— ——— ————
——————————
—
—
BOÎTE DE JONCTION
LIMIT CONTROL
———
— ————
——————————— —
CONTROL DE
TOLERANCE
AUTO FAN
———
—— ————
———————
—
VENTILATE
AUTO
TRANSFORMER
———
—— ————
——————————————
—
TRANSFORMATEUR
SPT-3 CORDSET
———
—— ————
———————————
—
CORDON SPT-3
GAS VALVE
———
—— ————
—————————
—
VALVE DE GAZ
WHITE (BLANC)
BLACK (NOIR)
MOTOR
————— ————
—
MOTEUR
ON/OFF DEVICE
———
— ————
——————————— —
ON/OFF
PÉRIPHÉRIQUES
WIRE NUT
—
— ————
———————---------------- —
FILS TORSADÉS