The appliance, when installed, must be electrically grounded 

in accordance with local codes or, in the absence of local 

codes, with the 

National Electrical Code, ANSI/NFPA 70 or 

Canadian Electrical Code, CSA C22.1,

 if an external electrical 

source is utilized. 

This appliance is equipped with a three-

prong [grounding] plug for your protection against shock 

hazard and should be plugged directly into a properly 

grounded three-prong receptacle. Do not cut or remove 

the grounding prong from this plug. 

For an ungrounded 

receptacle, an adapter, which has two prongs and a wire for 

grounding, can be purchased, plugged into the ungrounded 

receptacle and its wire connected to the receptacle mounting 

screw. With this wire completing the ground, the appliance 

cord plug can be plugged into the adapter and be electrically 

grounded. a

 7/8

" hole is provided in the junction box for use 

with a conduit connector if local codes require this type of 

protection.

CAUTION:

  Label all wires prior to disconnection when 

servicing controls. Wiring errors can cause improper 

and dangerous operation. Verify proper operation after 

servicing.

To Conserve Gas: Turn off pilot when heater is not in use.

Installing the ON/OFF Device

To install an ON/OFF device (such as a wall switch, remote, 

toggle switch, or thermostat), remove the wire nut from the 

two wires from the valve. Run additional wire from the valve 

wires to the ON/OFF device. Install the ON/OFF device in the 

same room as the furnace following the installation instruc-

tions supplied with it. In the absence of instructions, install the 

ON/OFF device 4 to 5 feet above the floor on an interior wall 

not affected by another heating source (i.e. stove or water 

heater) or the temperature of an adjoining room.

WIRING

IF ANY OF THE ORIGINAL WIRE AS SUPPLIED

WITH THIS UNIT MUST BE REPLACED, IT MUST

BE REPLACED WITH 150°C THERMOPLASTIC

4/64 THICK OR ITS EQUIVALENT.

120V. 60Hz. LESS THAN 3 AMPS

S´IL Y A UN FIL ORIGINAL FOURNI AVEC

L´APPAREIL QUI DIOT ÊTRE REMPLACÉ. IL DOIT

ÊTRE REMPLACÉ AVEC UN FIL

THERMOPLASTIQUE 150°C.

120V. 60Hz. MOINS DE 3 AMPS.

——————

————————————————————

———————————————————————————

VALVE DE GAZ

PÉRIPHÉRIQUES

120 VOLTS

LADDER WIRING DIAGRAM

——————————————————————————

DIAGRAMME À L´ÉCHELLE

D´INSTALLATION ÉLECTRIQUE

YELLOW

———

————————

JAUNE

WHITE

———

————————

BLANC

BLACK

———

————————

NOIR

RED

ROUGE

RED

ROUGE

TRANSFORMER

———

—— ————

——————————————

TRANSFORMATEUR

24 VOLTS

MOTOR

————— ————

MOTEUR

AUTO FAN

———

—— ————

———————

VENTILATEUR

AUTO

GAS VALVE

———

—— ————

—————————

LIMIT CONTROL

———

— ————

——————————— —

CONTROL DE

TOLERANCE

ON/OFF DEVICE

———

— ————

——————————— —

ON/OFF

WIRE NUT

— ————

———————---------------- —

FILS TORSADÉS

LOW VOLTAGE (BAS VOLTAGE)

120 VOLTS

SCHEMATIC WIRING DIAGRAM

——————————————————————————————

SCHÉMA

É

INSTALLATION LECTRIQUE

JUNCTION BOX

——

—— ——— ————

——————————

BOÎTE DE JONCTION

LIMIT CONTROL

———

— ————

——————————— —

CONTROL DE

TOLERANCE

AUTO FAN

———

—— ————

———————

VENTILATE

AUTO

TRANSFORMER

———

—— ————

——————————————

TRANSFORMATEUR

SPT-3 CORDSET

———

—— ————

———————————

CORDON SPT-3

GAS VALVE

———

—— ————

—————————

VALVE DE GAZ

WHITE (BLANC)

BLACK (NOIR)

MOTOR

————— ————

MOTEUR

ON/OFF DEVICE

———

— ————

——————————— —

ON/OFF

PÉRIPHÉRIQUES

WIRE NUT

— ————

———————---------------- —

FILS TORSADÉS

Содержание DVC55SPPXLP-1

Страница 1: ...combustion which can cause death or serious illness Installer Leave this manual with the appliance Consumer Retain this manual for future reference WARNING If the information in these instructions ar...

Страница 2: ...duction 6 Specifications 6 Gas Supply 7 8 Clearances 8 Installation Instructions 9 11 Lighting Instructions 12 Pilot Flame Characteristics 13 Main Burner Flame Characteristics 13 Wiring 14 Service and...

Страница 3: ...The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpet ing bedding materials etc It i...

Страница 4: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clo...

Страница 5: ...oxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be pe...

Страница 6: ...ied Installing Agency Installation and replacement of gas piping gas utilization equip ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency The term...

Страница 7: ...local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases The gas lines must be checked f...

Страница 8: ...distance from the center of the vent cap to the nearest outside corner or obstruction is 24 inches CLEARANCES Checking Manifold Pressure Both Propane and Natural gas valves have a built in pressure re...

Страница 9: ...provided Side outlet kit 10 boot assembly with register SOK 1 for warm air discharge into an adjoining room may be installed on either side of the furnace at the required clearance of 4 inches to adj...

Страница 10: ...ove old furnace cement from both ends of 4 diameter flue outlet tube 3 Attach 6 diameter air inlet tube onto the collar of air drop assembly Attach caulked outside mounting plate into the 6 diameter a...

Страница 11: ...e projection 2 x 4 framing whose outside dimensions match the overall dimensions of the mounting plate is recommended The 2 x 4 framing protects siding from possible warpage or discoloration All joint...

Страница 12: ...power to the appliance FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of l...

Страница 13: ...emovingthe burner door from the combustion chamber remove rear burner pilot burner and front burner With front and rear burners removed from furnace force water into the ribbon ports and dry with air...

Страница 14: ...toggle switch or thermostat remove the wire nut from the two wires from the valve Run additional wire from the valve wires to the ON OFF device Install the ON OFF device in the same room as the furnac...

Страница 15: ...r Does Not Light Pilot With air in the gas line such as when the furnace is first installed or was off all summer the pilot flame may be too lean to ignite on the first few trials Turn the control val...

Страница 16: ...l Gas 28 DV808 Pilot Tubing 29 DV824 Front Burner 30 P8842 Main Burner Orifice Natural Gas Two Required 30 P8853 Main Burner Orifice LP Gas Two Required 31 DV687 Manifold and Plate Assembly 32 M148 Ma...

Страница 17: ...Page 17 32188 0 0616 PARTS VIEW...

Страница 18: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numb...

Страница 19: ...le cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from t...

Страница 20: ...mfort Systems Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please cont...

Страница 21: ...rieuses maladies Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflammables dans le voisnage de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE...

Страница 22: ...st chaud lorsque le radiateur est en fonction L installation et la r paration doivent tre faites par une per sonne qualifi e L appareil doit tre inspect avant l usage et au moins une fois par ann e pa...

Страница 23: ...bas Attendez que les pompiers vous assurent de la s ret de ces endroits avant d y aller Utiliser le t l phone de votre voisin et appeler les pompiers et une personne entra n e avec le propane Ne pas...

Страница 24: ...e gaz d entrer par le capuchon de l vent Emplacement de l Ouverture dans le Mur Le radiateur doit tre situ sur un mur ext rieur Trouver les montants du mur ainsi l ouverture dans le mur sera entre les...

Страница 25: ...d espace libre aux mat riaux combus tibles venant du d gage ment du registre de chaque c t Entr e de gaz Enlever plinthe et moulure ouverture d vent 7 1 2 19cm Mur ar ri re Minimum d espace libre au c...

Страница 26: ...l entr e de la pluie Attacher la plaque ext rieure de montage au mur ext rieur avec 4 vis 10 x 1 38mm Les vis sont fournies 4 Appliquer du ciment pour radiateur au collet de la sortie Emplacement de l...

Страница 27: ...ourrev tementnedoitpasexc derune paisseur totale de 13 33 02cm pour le DV 55 voir Figure 5a AVERTISSEMENT Lorsque l ensemble d vent pour le rev tementenvinyleDV 822oulaconstructionfaitede2 x 4 5 08cm...

Страница 28: ...x et de raccords en m tal ondul ANS Z21 45 Connexions flexibles d appareil autre qu en m tal Les connexions ci dessus peuvent tre utilis es si elles sont accept es par les autorit s ayant juridiction...

Страница 29: ...index no 4 pi ce no 712059 Les joints d tanch it doivent tre tir s pour s adapter sur les boulons du moteur dans les espaces pour joint d tanch it Le moteur et les joints d tanch it peuvent tre insta...

Страница 30: ...tournerle bouton de contr le de gaz N utiliserjamais des outils Si vousnepouvezpaspousseroutournerleboutonavecvos mains n essayerpasdeler parer appeleruntechnicien qualifi Forcer ou essayer de r parer...

Страница 31: ...a veilleuse et r allumer La veilleuse s enflamme mais s teint lorsque le bouton est rel ch 1 Suivre les instructions et appuyer sur le bouton plus long temps et fermement 2 D terminer si la flamme de...

Страница 32: ...semblage du br leur avant 30 P8842 Br leur principal avec ouverture gaz naturel exige deux 30 P8853 Br leur principal avec ouverture gaz propane exige deux 31 DV687 Tuyau de gaz et assemblage de plaqu...

Страница 33: ...Page 13 32188 0 0616 Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 2623...

Страница 34: ...aiement pour attester de la date d achat et tablir la p riode de garantie Acc s imm diat l appareil pour la r paration Ce qui n est pas couvert Dommages pouvant r sulter de l emploi de l emploi abusif...

Страница 35: ...Page 15 32188 0 0616 NOTES DE SERVICE...

Страница 36: ...ire Comfort Systems Inc Belleville IL Pour toute question g n rale concernant nos produits veuillez nous envoyer un courriel info empirecomfort com Pour toute question d entretien ou de r paration veu...

Отзывы: