Mag 20 Furnace Assembly, Operation and Parts

Assembly

The main body of your furnace is fully assembled and factory-tested. To facilitate packag-

ing, the valve rod and operating lever have not been factory-installed and you must do so,
prior to using the furnace as follows: Attach the operating lever spring to the operating lever.
Slide the valve rod on the operating lever as shown in Figure 19. Next, place the valve rod
and operating lever, into position as shown in Figure 20. Fasten the operating lever using the
furnished 5/8" 6/32" screw. Insert the lever adjusting screw and hex locknut as shown. Your
furnace is now ready for use.
Handling Lead

Lead, a substance known to cause birth defects, reproductive harm and other severe physi-

cal injury, must be handled with extreme care. Handle lead bullets or lead shot only in a well
ventilated area and ALWAYS wash hands after handling lead and before eating. Discharging
firearms in poorly ventilated areas, cleaning firearms, or handling ammunition, also may
result in exposure to lead. Have adequate ventilation at all times.

Figure 19.

Figure 20.

WARNING: Melting lead and casting lead objects will

expose you and others in the area to lead, which is known to

cause birth defects, other reproductive harm and cancer.

REDUCING EXPOSURE:

Lead contamination in the air, in dust, and on your

skin is invisible.

Keep children and pregnant women away during use and until cleanup is complete.
Risk can be reduced — but not eliminated — with strong ventilation; washing hands imme-

diately after use of these products before eating or smoking; and careful cleaning of surfaces
and floors with disposable wipes, after lead dust has had a chance to settle. Use a lead spe-
cific cleaner with EDTA, or a high-phosphate detergent (like most detergents sold for electric
dishwashers) and bag used wipes for disposal.

Use Strong Ventilation

Mag 20 Furnace

Mag Dipper Furnace

Содержание Mag 20

Страница 1: ... and ALWAYS wash hands after handling lead and before eating Discharging firearms in poorly ventilated areas cleaning firearms or handling ammunition also may result in exposure to lead Have adequate ventilation at all times Figure 19 Figure 20 WARNING Melting lead and casting lead objects will expose you and others in the area to lead which is known to cause birth defects other reproductive harm ...

Страница 2: ...irst which can be a problem inside your house The temperature of your furnace is controlled by a positive action thermostat that senses the lead alloy temperature of the furnace The thermostat will cycle power to the furnace to maintain the desired casting temperature This furnace is equipped with a pilot light located adjacent to the thermostat control knob When this pilot light comes on it means...

Страница 3: ...d the foregoing placement techniques will greatly reduce the block warmup time to produce a good bullet and keep the handles cool too The Thermostat Your new Lyman electric furnace provides a full range of temperature adjustments The thermostat employed is one of the finest available and allows you to control the melt tempera ture to within 20 degrees repeatability In time your original thermostat...

Страница 4: ...on the track for sever al seconds until the sprue solidifies If an ingot mould is to be used with the furnace while the mould guide is in place set the ingot mould length wise either on top of it may be necessary to remove the mould stop or beneath the track and fill the cavity closest to the operator first Remaining cavities are filled by slowly drawing the ingot mould toward the operator Pliers ...

Страница 5: ...10 20 21 22 23 24 25 26 27 28 MAG 20 upper Visit our complete Lyman website at www lymanproducts com See Page 63 for parts Description ...

Страница 6: ...11 12 4 13 14 15 16 17 18 19 33 35 34 36 37 12 29 30 31 32 16 29 12 MAG 20 lower Visit our complete Lyman website at www lymanproducts com ...

Страница 7: ...1 4 20 x 1 2 3 2800088 20 Shut Off Rod 2999085 21 Lever Spring 2999087 22 Lever 2999086 23 Knob Stud 7994420 24 Lever Knob 7994419 25 Indicator Light 2800072 26 Pan Head Screw 6 32 x 1 4 2800089 27 Thermostat Knob 2800077 28 Thermostat 110V 2800071 29 Washer 5 2800091 30 Strain Relief Bushing 2800094 31 Channel 2800095 32 Electric Cord 110V 2800070 33 Hex Nut 10 24 2990075 34 Post Support 2 299069...