31455-4-1113
Page 9
The following vent systems are acceptable for use with the
DVP (42,48) series fireplaces:
Simpson Duravent® GS 5" - 8"
American Metal Products 5" - 8"
Selkirk Direct-Temp® 5" - 8"
Security Secure Vent® 5" - 8"
Excel DV Venting 5” - 8”
Empire Flexvent Kit DVVK-5F
The following vent systems are acceptable for use with the DVA-47
adaptor vertically off top of fireplace only:
Simpson Duravent
®
GS 4" - 6⅝"
American Metal Products 4" - 6⅝"
Selkirk Direct-Temp® 4" - 6⅝"
Security Secure Vent® 4" - 6⅝"
Excel DV Venting 4” - 6⅝”
Empire Horizontal Round Termination Kit DVVK-4RE
Note: DVA-47 Not for use with Flex Vent Kits. For use with Simpson
Duravent vents only.
Figure 2
FIREPLACE DIMENSIONS
A
B
C
D
E
F
G
H
I
J
K
DVP42
43”
(1092mm)
40”
(1016mm)
25 1/16”
(636 mm)
37 5/8”
(956 mm)
34 3/4”
(883 mm)
19 7/8”
(505 mm)
26”
(660 mm)
7 1/8”
(181 mm)
26 1/2”
(826 mm)
13 1/4”
(337 mm)
12 3/4”
(324 mm)
DVP48
49”
(1245mm)
46”
(1168mm)
25 1/16”
(636 mm)
37 5/8”
(956 mm)
34 3/4”
(883 mm)
19 7/8”
(505 mm)
26”
(660 mm)
7 1/8”
(181 mm)
32 1/2”
(826 mm)
16 1/4”
(413 mm)
12 3/4”
(324 mm)
SPECIAL VENT SYSTEMS
Содержание DVP42 Series
Страница 20: ...31455 4 1113 Page 20 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN...
Страница 42: ...31455 4 1113 Page 42 Figure 75 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 54: ...31455 4 1113 Page 54 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 64: ...31455 4 1113 Page 64 PARTS VIEW...