
31455-4-1113
Page 11
Figure 7
NOTICE
:
Island and Room Divider installation is possible as long
as the horizontal portion of the vent system does not exceed 20 feet
with a minimum vertical run of 8 feet. See details in Venting Section.
When you install your Direct Vent Fireplace in Room divider or Flat
on wall corner positions, a minimum of 6 inches clearance must
be maintained from the perpendicular wall and the front edge of
the appliance.
CABINET
INSTALLATION
FLUSH WALL
INSTALLATION
ROOM DIVIDER
INSTALLATION
CORNER
INSTALLATION
ANGLED CORNER
INSTALLATION
ISLAND
INSTALLATION
LOCATING FIREPLACE
Содержание DVP42 Series
Страница 20: ...31455 4 1113 Page 20 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN...
Страница 42: ...31455 4 1113 Page 42 Figure 75 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 54: ...31455 4 1113 Page 54 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 64: ...31455 4 1113 Page 64 PARTS VIEW...