VENT SYSTEM IDENTIFICATION
Figure 1
Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if the
fireplace is to be vented out the top or out the rear.
NOTICE:
Some fireplaces cannot be vented out the rear of the
fireplace.
Determine how the vent system will be terminated out the side of
the house or through the roof. Verify clearances for the termination.
When selecting a vent system for use with the fireplace, refer to
the “Special Vent Systems” section in this manual to determine
what systems are acceptable. Check all clearances and venting
components. Identify if any problems existing in the vent system.
Use
Figure 22
on page 17 for top venting, or
Figure 35
on page
22 for rear venting to eliminate issues after installation. Check pipe
diameter on vent system and fireplace to verify the size is the same.
NOTICE
: All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C. The inner flue joints do not require any sealant.
Special Venting Components (Simpson Duravent)
See Empire Comfort Systems Retail Price List for Simpson Duravent part num
-
bers and pricing.
Special DV Vent Kits Available from Empire Comfort Systems, Inc. dealers.
DVVK-4VP
(DVVK-4V)
Direct-Vent Fireplace Vent Kit - Vertical, Includes 46DVA-VCH,
46DVA-F6 and 46DVA-SC
DVVK-4RE
Direct-Vent Fireplace Vent Kit, Thru-the-wall, for 5 to 13 3/4 inch
wall thickness
DVVK-4TP
(DVVK-4T)
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 8 to 11
inch wall thickness, Includes 46DVA-HC, 46DVA-E90, 46DVA-09,
46DVA-08A and 46DVA-WT
DVVK-4TSP
(DVVK-4TS)
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 5 to 7
inch wall thickness, Includes 46DVA-HC, 46DVA-E90, 46DVA-06
and 46DVA-WT
DVVK-5RP
(DVVK-5R)
Direct-Vent Fireplace Vent Kit for Rear Vent, 6 to 12 inch wall
thickness, Includes SD-1208, SD-1247, and SD-1284
DVVK-5TP
(DVVK-5T)
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 4 to 6
inch wall thickness, Includes SD-1290, SD-1284, SD-1208 and
SD-1247
DVVK-5VP
(DVVK-5V)
Direct Vent Fireplace Vent Kit - Vertical, Includes SD-1291,
SD-1253, and SD-1243
DVVK-5TS
Top Vent Kit (Horizontal) - 4½” to 6” wall thickness (114.3mm to
152mm)
DVVK-5F
Horizontal Flex Vent Kit (4’ Flex) (1.22m)
Note: All DVVK-4 Vent Kits require use of the DVA47 adaptor.
*Note:
If using three 90° elbows during horizontal
termination, see
Figure 30.
Содержание DVP42 Series
Страница 20: ...31455 4 1113 Page 20 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN...
Страница 42: ...31455 4 1113 Page 42 Figure 75 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 54: ...31455 4 1113 Page 54 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 64: ...31455 4 1113 Page 64 PARTS VIEW...