Remote Control Options And Accessories
Description
FRBC
Millivolt/IP Battery Remote ON/OFF
FRBTC
Millivolt/IP Battery Remote T-Stat
TMW
Millivolt/IP WIRELESS Wall Thermostat
TRW
Millivolt/IP REED SWITCH Wall Thermostat
FWS-1
Millivolt/IP Wall Switch
FREC
Electric Remote
FBB4
Blower assembly
DVP42
DVP48
Input Btu/hr Maximum
28,000 (Natural)
28,000 (Propane)
30,000 (Natural)
30,000 (Propane)
Btu/hr Minimum (millivolt only)
19,000 (Natural)
22,000 (Propane)
20,500 (Natural)
24,000 (Propane)
kWH (Maximum)
8.2
8.8
(Minimum)
5.5
6.0
NATURAL
Orifice
#38 (.1015) P-203 - (DVP42FP(3,7,9))
#37 (.1040) P-213 - (DVP48FP(3,7,9))
air Shutter Opening
1/8"(3.2mm)
1/8"(3.2mm)
PROPANE
Orifice
#52 (.0635") P-185
1.65MM P-250
air Shutter Opening
FULL OPEN
FULL OPEN
Height without standoff
34 3/4"(883mm)
34 3/4"(883mm)
Width
43"(1092mm)
49"(1245mm)
Depth
19 7/8"(505mm)
19 7/8"(505mm)
Gas Inlet Shutoff Valve (Pipe)
1/2 NPT
1/2 NPT
NOTICE:
air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
SPECIFICATIONS
FIREPLACE BARRIER SCREENS
Model
Description
Used On
DVFB42TBL
Fireplace Barrier Screen, Matte Black
DVP42FP
DVFB48TBL
Fireplace Barrier Screen, Matte Black
DVP48FP
NOTICE:
A firescreen is required for operation of the appliance, but are sold separately. Follow the instructions that come with your fire-
screen for proper installation.
CONVERSION KITS
Models
Description
Part Numbers
DVP42FP3(0,1)
Propane to Natural
18824
DVP42FP3(0,1)
Natural to Propane
18821
DVP42FP7(0,1)
Propane to Natural
32016
DVP42FP7(0,1)
Natural to Propane
32021
DVP42FP91
Propane to Natural
35462
DVP42FP91
Natural to Propane
35463
DVP48FP3(0,1)
Propane to Natural
18825
DVP48FP3(0,1)
Natural to Propane
18822
DVP48FP7(0,1)
Propane to Natural
32017
DVP48FP7(0,1)
Natural to Propane
32022
DVP48FP91
Propane to Natural
35464
DVP48FP91
Natural to Propane
35445
Содержание DVP FP3 4 Series
Страница 20: ...39359 0 1018 Page 20 Figure 30 Figure 31 EXAMPLES TOP VENT RUN Figure 29...
Страница 41: ...39359 0 1018 Page 41 1 Place Log A 1 onto two pins on rear log support as shown below LOG PLACEMENT DVP 42 48...
Страница 45: ...39359 0 1018 Page 45 5 Log assembly is completed LOG PLACEMENT DVP 42 48...
Страница 48: ...39359 0 1018 Page 48 Figure 74 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 56: ...39359 0 1018 Page 56 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 83: ...39359 0 1018 Page 83 FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...