39359-0-1018
Page 34
NOTICE:
For top vent installation only: Use of a DVa47 adaptor
is required.
CAUTION
Sharp edges, use protective gloves when installing.
Tools Needed for Installation:
•
Sheet metal snips
•
5/16” nut driver
•
Phillips head screwdriver - #2
•
High temperature sealant or furnace cement rated for
continuous use at 1,000
o
F minimum
•
Measuring tape
Parts Verification
See parts list on page 36 to verify components included in this vent
kit prior to installation.
NOTICE:
a DVa47 adaptor must be used in conjunction with the
DVVk4RE (top vent connection only).
See Figure 59.
NOTICE:
If installing onto wood, lap, or vinyl siding, the vinyl siding
kit should be used (sold separately, part number DV-822).
The vinyl siding vent kit, DV-822, is available from Empire Comfort
Systems, Inc. The depth is 3” (76mm), which enables the vent
cap to be extended away from vinyl siding or projections. The wall
depth plus the additional 3” (76mm) depth of the vinyl siding vent
cap extension should not exceed a total depth of 13 3/4” (349mm).
If wall depth exceeds 13 3/4” (349mm), extend system using
6 5/8” (168mm) x 4” (102mm) rigid venting (See Fireplace Instruc-
tions for approved lengths)
See Figure 59.
Installing Wall Thimble/Firestop Assembly
1. Fix fireplace to permanent location. If using rigid venting system,
install up to the location where it will exit the building.
2. Cut hole in wall for wall thimble/firestop assembly (
Figure 58
)
into your combustible wall. Note: On brick or block exterior wall
a 7” (178mm) diameter hole needs to be cut.
Measure the total wall thickness to determine whether or not the
extension thimble is to be used. If the combustible wall depth
is over 5 3/8” (137mm), then the extension thimble should be
used.
See Figure 58.
3. Install the wall thimble assembly through the framed opening so
the firestop plate is on the interior wall (
Figure 58
). Telescope
section should extend all the way through the exterior wall.
attach with four 10 x 1” screws.
4. When placing the vent cap on an exterior wall covered with
combustibles such as wood, lap, or vinyl siding, install the vinyl
siding kit to the exterior wall sheathing.
Figure 58
Figure 59
Cutting Vent Tubes
This is the most important part of the installation.
With the
fireplace (and the rigid venting system if used) fixed to its perma-
nent location, the 6 5/8” (168mm) diameter air inlet tube and the 4”
(102mm) diameter flue outlet tube are to be marked and cut using
the following procedure.
5. attach the inlet tube to the outside mounting plate. align
tinnerman clips on the tabs of the air inlet tube to the holes
on outside mounting plate, and fix with two #10 x 1/2” screws.
6. With the vinyl siding kit installed to wall (if necessary), insert
the 6 5/8” (168mm) diameter tube with outside mounting plate
attached through hole in wall. Connect to collar on fireplace or
rigid vent system. Measure between wall or vent cap extension
and outside mounting plate.
See Figures 60 and 61.
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS
Содержание DVP FP3 4 Series
Страница 20: ...39359 0 1018 Page 20 Figure 30 Figure 31 EXAMPLES TOP VENT RUN Figure 29...
Страница 41: ...39359 0 1018 Page 41 1 Place Log A 1 onto two pins on rear log support as shown below LOG PLACEMENT DVP 42 48...
Страница 45: ...39359 0 1018 Page 45 5 Log assembly is completed LOG PLACEMENT DVP 42 48...
Страница 48: ...39359 0 1018 Page 48 Figure 74 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 56: ...39359 0 1018 Page 56 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 83: ...39359 0 1018 Page 83 FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...