39359-0-1018
Page 10
CLEARANCES
Clearance to Combustibles
Back
0" (0 mm)
Side
0" (0 mm)
Floor
0" (0 mm)
Top Stand-off
0" (0 mm)
Top Framing Edge
3" (76 mm)
Note A: See Figure 5
for maximum mantel depth.
Note B: See Figure 5
for minimum height above unit.
Figure 3
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
Figure 4
Mantel Chart
Figure 5
Clearances
Clearance from top front edge of fireplace to ceiling is 36”
Clearance from side of fireplace to adjacent sidewall is 6”.
See Figure 6.
(914mm)
Figure 6