REAR VENT CONVERSION
Converting flue take-off to rear venting
When switching out the flue and inlet vent collars to run horizontally
off the rear vent, the following steps must be taken.
1. Remove the inlet vent collar (8 screws) and flue collar (4 screws)
from the top of the fireplace, and set to the side.
2. Remove the inlet cover plate and flue cover plate located on
the back of the fireplace. These will be used to close the top
flue and inlet openings.
3. Insert the insulation retainer bracket and insulation into the top
flue pipe before reinstalling the flue cover plate over the top
flue with 4 screws.
4. Reinstall the inlet cover plate over the top inlet opening with 4
screws. See illustration above.
5. Install the flue collar assembly to the rear flue with 4 screws.
6. Install the inlet vent collar to the rear of the fireplace with 8
screws.
7. This completes the conversion for a rear vent application.
WARNING
For top vented installations, the insulation and retainer are
to be removed from the flue pipe and discarded.
Figure 40
Содержание DVP FP3 4 Series
Страница 20: ...39359 0 1018 Page 20 Figure 30 Figure 31 EXAMPLES TOP VENT RUN Figure 29...
Страница 41: ...39359 0 1018 Page 41 1 Place Log A 1 onto two pins on rear log support as shown below LOG PLACEMENT DVP 42 48...
Страница 45: ...39359 0 1018 Page 45 5 Log assembly is completed LOG PLACEMENT DVP 42 48...
Страница 48: ...39359 0 1018 Page 48 Figure 74 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 56: ...39359 0 1018 Page 56 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 83: ...39359 0 1018 Page 83 FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...