39359-0-1018
Page 40
LOG PLACEMENT (4 LOG SET)
Before you begin: If you are installing logs into the DVP42 or DVP48
model then this fireplace is supplied with a set of four ceramic fiber
logs. Do not handle these logs with your bare hands. always wear
gloves to prevent skin irritation from ceramic fibers. After handling
logs, wash your hands gently with soap and water to remove any
traces of fiber.
The positioning of logs is critical to safe and clean operation of this
fireplace. Sooting and other problems may result if the logs are not
properly and firmly positioned in the fireplace. Please refer to
Figure
69, Figure 70,
and
Figure 71
and corresponding
WARNING,
when
completing the following log placement steps.
1. Remove top louver, grasp louver, lift and pull forward.
2. Lower bottom louver, lift and hinge forward.
3. Release two glass frame spring clamps at bottom of firebox
NOTE:
For step by step log placement instructions with images,
see pages 41-45.
ATTENTION
: Do not place decorative rock on logs or on burner.
The decorative rock should only be placed on the fireplace floor.
Ember Placemen
t
1. Place decorative rock in front of grates and sides of main burner.
2. after all logs are properly positioned, place small “dime” size
pieces of Rockwool lightly across the front round “blueflame”
ports. Place the ember material (Rockwool pieces) side by side.
Do not stack more than one layer of embers across the burner
ports.
See Figure 69.
3. Replace glass door onto firebox.
4. Secure the two glass frame spring clamps at bottom of firebox.
5. align the tabs on top louver brackets with slots in front posts
to secure top louver.
6. Close bottom louver. Lift slightly to engage the end tabs into
the slots in fireplace sides to close louver panel.
Figure 70
LOG SET PARTS LIST
INDEX
NO.
PART NO.
DESCIPTION
DVP42
DVP48
!
R10349
R10357
REaR LOG
2
R10350
R10358
FRONT LEFT LOG
3
R10351
R10359
FRONT RIGHT LOG
4
R10352
R10360
TOP BRaNCH
Figure 71
WARNING
Failure to position the parts in accordance with this diagram
or failure to use only parts specifically approved with this
appliance may result in property damage or personal injury.
Figure 69
WARNING
If flame lifts off burner and goes out, verify insulation and
retainer were removed. See page 24.
Содержание DVP FP3 4 Series
Страница 20: ...39359 0 1018 Page 20 Figure 30 Figure 31 EXAMPLES TOP VENT RUN Figure 29...
Страница 41: ...39359 0 1018 Page 41 1 Place Log A 1 onto two pins on rear log support as shown below LOG PLACEMENT DVP 42 48...
Страница 45: ...39359 0 1018 Page 45 5 Log assembly is completed LOG PLACEMENT DVP 42 48...
Страница 48: ...39359 0 1018 Page 48 Figure 74 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 56: ...39359 0 1018 Page 56 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 83: ...39359 0 1018 Page 83 FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...