37754-6-1019
Page 30
Determine how the vent system will be terminated out the side of
the house or through the roof.
Select the type of venting and the path it will take. Verify
clearances throughout the path. Refer to the “Special Vent
Systems” section in this manual to determine what systems are
acceptable. Check all clearances and venting.
NotICE:
This fireplace cannot be vented out the rear.
Verify clearances for the termination.
Identify if any problems exist in the vent system. Use
Figure ??
on page 35 for top venting to eliminate issues after installation.
Check pipe diameter on vent system and fireplace to verify the
size is the same.
NotICE
:
All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C. The inner flue joints do not require any sealant.
VENT SYSTEM IDENTIFICATION
Special DV Vent kits
Available from Empire Comfort Systems, Inc. dealers.
DVVK-5RP
Direct-Vent Fireplace Vent Kit for Rear Vent,
6 to 12-inch wall thickness, Includes
58DVA-06, 58DVA-WT, and 58DVAHC
DVVK-5TP
Direct-Vent Fireplace Vent Kit for Top Vent,
Thru-the-wall, 4-inch to 6-inch wall thickness,
Includes 58DVA-E90, 58DVA-HC, 58DVA-06,
and 58DVA-WT
DVVK-5VP
Direct-Vent Fireplace Vent Kit - Vertical,
Includes 58DVA-VCH, 58DVA-SC, and
58DVA-F6
DVVK-5TS
Top Vent Kit (Horizontal) - 4½-inch to 6-inch
wall thickness (114.3 mm to 152 mm)
*DVVK-5F
Horizontal Flex Vent Kit (4' Flex) (1.22m)
*Requires 6 inch hard pipe off top of fireplace.
VENT SYSTEMS
This fireplace requires 5 inches x 8 inches Direct-Vent venting.
In addition to the Empire kits on this page, the following vent
systems are approved for use with the DVLL48SP series
fireplaces:
Duravent® GS
American Metal Products
Selkirk Direct-Temp®
Security Secure Vent®
Excel DV Venting
Empire Flexvent Kit DVVK-5F
BDM
Metal Fab
FLASHING
STORM
COLLAR
VERTICAL
TERMINATION
(THREE 90°
ELBOWS MAX)
WALL
THIMBLE
HORIZONTAL
TERMINATION
(THREE 90°
ELBOWS MAX)
90° ELBOW
OR
45° ELBOW
90° ELBOW
CEILING
FIRE STOP
WALL STRAP
PIPE LENGTH
Figure 35